Detectible Distance 5m, M12 Connector Cable, Class 1 Laser
- Code / Model:
- Manufacturer: Keyence
- Department: Connectors
- Category of products: Circular connectors
- Sub-category: Industrial circular connectors
- You've seen it before.: 1
Model
LR-TB5000CL
Type
Cable with M12 Connector
Detectable Distance
60 to 5000 mm (2.36" to 196.85")*1
Spot Diameter
Variable (Use a spot diameter of 40 mm (1.57") or less)
Response Time
Selectable: 2 ms/20 ms/50 ms/200 ms/2000 ms
Light Source
Type
Red Laser (660 nm)
Laser Class
Class 1 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)
Mutual Interference Prevention Function
4 units (when using the mutual interference prevention function)
Timer
- OFF
- OFF Delay
- ON Delay
- Single Shot
Power Supply Voltage
20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS
Current Consumption
50 mA or less (no load)*3
I/O
Control Output
Selectable: NPN Open Collector / PNP Open Collector
30 VCD or less, 50 mA or less, Residual Voltage: 2 V or less,
N.A./N.C. selectable*4 *5
Protection Circuit
- Reverse Power Supply Connection Protection
- Power Surge Protection
- Output Overcurrent Protection
- Output Reverse Connection Protection
- Output Surge Protection
Environmental Resistance
Degree of Protection
IP65/IP67 (IEC60529)
Ambient Light
Incandescent Lamp / Sunlight: 10,000 lux or less
Ambient Temperature
-20 to +55 °C (-4 to 131 °F) (No Freezing)
Relative Humidity
35 to 85% HR (No Condensation)
Vibration Resistance
10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions
Shock Resistance
1,000 m/s² , 6 times in each of the X, Y, and Z directions
Material
- Housing: Zinc Die-Casting (Nickel Plated)
- Indicator and Button Cover: PES
- Lens and Display Cover: PMMA (Scratch-Resistant Coating Specifications)
- Cable Bush: PBT
- Cable: PVC
- M12 Connector: TPE, PBT, Nickel Plated Brass
Accessories
Instruction Manual
Weight
Approx. 160 g
*1 The visible distance range is from 50 to 5200 mm. *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations: Output Control × 2, Output Control + External Input Output Control + Analog Output (Only LR-TB5000/TB5000C/TB5000CL) External Input + Analog Output (Only LR-TB5000/TB5000C/TB5000CL) (For more details on the configuration method, refer to the instruction manual). *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.