Detectible Distance 5m, M12 Connector Cable, Class 1 Laser

Detectible Distance 5m, M12 Connector Cable, Class 1 Laser

Model

LR-TB5000CL

Type

Cable with M12 Connector

Detectable Distance

60 to 5000 mm (2.36" to 196.85")*1

Spot Diameter

Variable (Use a spot diameter of 40 mm (1.57") or less)

Response Time

Selectable: 2 ms/20 ms/50 ms/200 ms/2000 ms

Light Source

Type

Red Laser (660 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)

Mutual Interference Prevention Function

4 units (when using the mutual interference prevention function)

Timer

  • OFF
  • OFF Delay
  • ON Delay
  • Single Shot

Power Supply Voltage

20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS

Current Consumption

50 mA or less (no load)*3

I/O

Control Output

Selectable: NPN Open Collector / PNP Open Collector

30 VCD or less, 50 mA or less, Residual Voltage: 2 V or less,

N.A./N.C. selectable*4 *5

Protection Circuit

  • Reverse Power Supply Connection Protection
  • Power Surge Protection
  • Output Overcurrent Protection
  • Output Reverse Connection Protection
  • Output Surge Protection

Environmental Resistance

Degree of Protection

IP65/IP67 (IEC60529)

Ambient Light

Incandescent Lamp / Sunlight: 10,000 lux or less

Ambient Temperature

-20 to +55 °C (-4 to 131 °F) (No Freezing)

Relative Humidity

35 to 85% HR (No Condensation)

Vibration Resistance

10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions

Shock Resistance

1,000 m/s² , 6 times in each of the X, Y, and Z directions

Material

  • Housing: Zinc Die-Casting (Nickel Plated)
  • Indicator and Button Cover: PES
  • Lens and Display Cover: PMMA (Scratch-Resistant Coating Specifications)
  • Cable Bush: PBT
  • Cable: PVC
  • M12 Connector: TPE, PBT, Nickel Plated Brass

Accessories

Instruction Manual

Weight

Approx. 160 g

*1 The visible distance range is from 50 to 5200 mm. *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations: Output Control × 2, Output Control + External Input Output Control + Analog Output (Only LR-TB5000/TB5000C/TB5000CL) External Input + Analog Output (Only LR-TB5000/TB5000C/TB5000CL) (For more details on the configuration method, refer to the instruction manual). *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.