Detectable Distance 2m, M12 Connector Cable, Class 1 Laser

Detectable Distance 2m, M12 Connector Cable, Class 1 Laser

Model

LR-TB2000CL

Type

Cable with M12 Connector

Detectable Distance

60 to 2000 mm (2.36" to 78.74")*1

Spot Diameter

Approx. 4 mm (0.16")

Response Time

Selectable: 2 ms/20 ms/50 ms/200 ms/2000 ms

Light Source

Type

Red Laser (660 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)

Mutual Interference Prevention Function

4 units (when using the mutual interference prevention function)

Timer

  • OFF
  • OFF Delay
  • ON Delay
  • Single Shot

Power Supply Voltage

20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS

Current Consumption

45 mA or less (no load)*3

I/O

Control Output

Selectable: NPN open collector / PNP open collector

30 VCD or less, 50 mA or less, Residual voltage: 2 V or less,

N.O./N.C. selectable*4 *5

Analog Output

-

Protection Circuit

  • Reverse polarity protection of the power supply
  • Power surge protection
  • Output overcurrent protection
  • Reverse connection protection of output
  • Output surge protection

Environmental Resistance

Degree of Protection

IP65/IP67 (IEC60529)

Ambient Light

Incandescent lamp / Sunlight: 10,000 lux or less

Ambient Temperature

-20 to +55 °C (-4 to 131 °F) (No freezing)

Relative Humidity

35 to 85% HR (No condensation)

Vibration Resistance

  • 10 to 55 Hz, Double amplitude 1.5 mm (0.06")
  • 2 hours in each of the X, Y, and Z directions

Shock Resistance

1,000 m/s²*2, 6 times in each of the X, Y, and Z directions

Material

  • Housing: Zinc die-cast (nickel plated)
  • Indicator and button cover: PES
  • Lens and display cover: PMMA (scratch-resistant coating specifications)
  • Cable bushing: PBT
  • Cable: PVC
  • M12 connector: TPE, PBT, nickel plated brass

Accessories

Instruction Manual

Weight

Approx. 85 g

Notes

  • *1 The visible distance range is 50 to 2200.
  • *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50.
  • *3 145 mA or less (with load)
  • *4 You can select the I/O from the following combinations.
    • Control output × 2, control output + external input
    • Control output + analog output (only LR-TB5000/TB5000C/TB5000CL)
    • External input + analog output (only LR-TB5000/TB5000C/TB5000CL)

    (For more details on the configuration method, refer to the instruction manual).

  • *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the Internet, please contact your nearest KEYENCE office.