Detectable Distance 2m, M12 Connector Cable, Class 1 Laser
- Code / Model:
- Manufacturer: Keyence
- Department: Connectors
- Category of products: Circular connectors
- Sub-category: Industrial circular connectors
- You've seen it before.: 1
Model
LR-TB2000CL
Type
Cable with M12 Connector
Detectable Distance
60 to 2000 mm (2.36" to 78.74")*1
Spot Diameter
Approx. 4 mm (0.16")
Response Time
Selectable: 2 ms/20 ms/50 ms/200 ms/2000 ms
Light Source
Type
Red Laser (660 nm)
Laser Class
Class 1 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)
Mutual Interference Prevention Function
4 units (when using the mutual interference prevention function)
Timer
- OFF
- OFF Delay
- ON Delay
- Single Shot
Power Supply Voltage
20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS
Current Consumption
45 mA or less (no load)*3
I/O
Control Output
Selectable: NPN open collector / PNP open collector
30 VCD or less, 50 mA or less, Residual voltage: 2 V or less,
N.O./N.C. selectable*4 *5
Analog Output
-
Protection Circuit
- Reverse polarity protection of the power supply
- Power surge protection
- Output overcurrent protection
- Reverse connection protection of output
- Output surge protection
Environmental Resistance
Degree of Protection
IP65/IP67 (IEC60529)
Ambient Light
Incandescent lamp / Sunlight: 10,000 lux or less
Ambient Temperature
-20 to +55 °C (-4 to 131 °F) (No freezing)
Relative Humidity
35 to 85% HR (No condensation)
Vibration Resistance
- 10 to 55 Hz, Double amplitude 1.5 mm (0.06")
- 2 hours in each of the X, Y, and Z directions
Shock Resistance
1,000 m/s²*2, 6 times in each of the X, Y, and Z directions
Material
- Housing: Zinc die-cast (nickel plated)
- Indicator and button cover: PES
- Lens and display cover: PMMA (scratch-resistant coating specifications)
- Cable bushing: PBT
- Cable: PVC
- M12 connector: TPE, PBT, nickel plated brass
Accessories
Instruction Manual
Weight
Approx. 85 g
Notes
- *1 The visible distance range is 50 to 2200.
- *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50.
- *3 145 mA or less (with load)
- *4 You can select the I/O from the following combinations.
- Control output × 2, control output + external input
- Control output + analog output (only LR-TB5000/TB5000C/TB5000CL)
- External input + analog output (only LR-TB5000/TB5000C/TB5000CL)
- *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the Internet, please contact your nearest KEYENCE office.