Base Unit Type 40 Points AC Power Supply Relay
- Code / Model:
- Manufacturer: Keyence
- Department: Unclassified
- Category of products: Unclassified
- Sub-category: Unclassified
- You've seen it before.: 1
General Specifications
Power Supply Voltage
- 100 to 240 VAC (+10 %/-15 %)
Output Voltage of Power Supply
- 24 VDC (±10 %; output capacity: 0.6 A)
Ambient Temperature
- 0 to 55 °C (32 to 131 °F) (without freezing)
Storage Temperature
- -25 to +75 °C (-13 to +167 °F)
Ambient Humidity
- 5 to 95 % HR (without condensation)
Supported Voltage
- 1500 VAC for 1 minute, between power terminals and I/O terminals, and between all external terminals and the housing
Noise Immunity
- 1500 V peak-to-peak or more, pulse duration 1 µs, 50 ns (based on noise simulator), conforming to IEC standard (IEC61000-4-2/3/4/6)
Vibration Resistance
- Intermittent Vibration
- Frequency 5 to 9 Hz
- Amplitude: 3.5 mm (0.14")
- Frequency 9 to 150 Hz
- Acceleration: 9.8 m/s2
- Continuous Vibration
- Frequency 5 to 9 Hz
- Amplitude: 1.75 mm (0.07")
- Frequency 9 to 150 Hz
- Acceleration: 4.9 m/s2
Shock Resistance
- Acceleration: 150 m/s2, application time: 11 ms; three times in each of the X, Y and Z directions
Insulation Resistance
- 50 MΩ or more (megohmmeter of 500 VCD used to perform measurements between power terminal and input terminals, and between all external terminals and the housing)
Operating Environment
Dust and Corrosive Gas
- As little as possible
Operating Altitude
- 2000 m (6600') or less
Overvoltage Category
- AC: II, DC: I
Pollution Degree
- 2
Performance Specifications
Calculation Control Method
Program Storage Method
I/O Control Method
Update Method
Programming Language
- Expanded Ladder, KV Script, mnemonic
Number of Instructions
- Basic Instruction: 81 types and 182 instructions, Application Instruction: 39 types and 56 instructions, Calculation Instruction: 123 types and 311 instructions, Expansion Instruction: 92 types and 141 instructions, Total: 335 types and 690 instructions
Instruction Execution Speed
- Basic Instruction: 50 ns minimum, Application Instruction: 170 ns minimum
Program Capacity
- 16k steps
Maximum Number of Connectable I/O Units
- 8
Maximum Number of I/O Points
- 256 (excluding I/O of the base unit)
Relay Input/Output/Internal Auxiliary Relay
- R: Total of 9600 1-bit points (R000 to R59915)
Retention Relay
- B: 8192 1-bit points (B0 to B1FFF)
Internal Auxiliary Relay
- MR: 9600 1-bit points (MR000 to MR59915)
Retention Relay
- LR: 3200 1-bit points (LR000 to LR19915)
Control Relay
- CR: 1440 1-bit points (CR000 to CR8915)
Timer
- T: 512 32-bit points (T0 to T511)
Counter
- C: 256 32-bit points (C0 to C255)
Data Memory
- DM: 32768 16-bit points (DM0 to DM32767)
Link Register
- W: 16384 16-bit points (W0 to W3FFF)
Temporary Memory
- TM: 512 16-bit points (TM0 to TM511)
High-Speed Counter
- CTH: 3 points (CTH0 to CTH2)
32-bit Automatic Reset Counter
- *5 (Input response: 100 kHz per single phase, 50 kHz per phase difference) *6
High-Speed Counter Comparator
- CTC: 6 points (CTC0 to CTC5), 32 bits, two points per high-speed counter
Index Register
- Z: 12 32-bit points (Z01 to Z12)
Control Memory
- CM: 9000 16-bit points (CM0 to CM8999)
Base Unit of I/O
- Input: 24 points, Output: 16 points
Common Input/Output Points (Type R):
- 1 point (common input), 6 points (common output)
Common Input/Output Points (Type T/TP):
- 2 points
Number of Comments/Tags Stored in the Main Unit
- Device Comment: 20000, When writing a ladder program of maximum length, without tags.
- Tag: 28000, When writing a ladder program of maximum length, without device comments.
Power-Off Retention Function
- Program Memory: Can be rewritten 10000 times (Flash ROM)
Self-Diagnosis Function
- CPU error, RAM error, and other problems
Input Specifications
Number of Relays
- General Input: R000 to R007, R0014 to R107 (18 points)
- High-Speed Phase A and Phase B Input: R008 to R013 (3 channels, 6 points in total)
Input Mode
- 24 VCD (collector open)
Maximum Input Voltage
- 26.4 VCD
Nominal Input Voltage
- 24 VCD (General Input: 5.3 mA, High-Speed Phase A and Phase B Input: 6.5 mA *8)
Minimum ON Voltage
- 19 VCD
Maximum OFF Current
- 1.5 mA
Common Point Mode
- General Input: All points/1 common (1 terminal), High-Speed Phase A and Phase B Input: Common shared for all points (shared with general input)
Circuit Delay Time
- General Input:
- OFF to ON: Max. 30 µs (Typ. 3.5 µs), ON to OFF: Max. 50 µs (Typ. 15 µs)
- High-Speed Phase A and Phase B Input:
- OFF to ON: Max. 2 µs (Typ. 1.1 µs), ON to OFF: Max. 2 µs (Typ. 0.3 µs)
Input Time Constant
- Normal: 10 ms, When using the HSP instruction: 10 µs, When CR2305 is ON: 10 µs to 10 ms, eight-level switching possible (configured with CM1620). Can also be configured from the Unit Editor. *9
Input Time Constant Delay
- Input time constant adjustment of 10 µs: Digital filter 1.6 to 2 µs, Input time constant adjustment of 20 µs: Digital filter 9 to 12 µs, Input time constant adjustment of 110 µs: Digital filter 90 to 93 µs, Input time constant adjustment of 500 µs: Digital filter 300 to 400 µs, Input time constant adjustment of 1 ms: Digital filter 800 to 900 µs, Input time constant adjustment of 2.5 ms: Digital filter 2.3 to 2.4 ms, Input time constant adjustment of 5 ms: Digital filter 4.0 to 4.5 ms, Input time constant adjustment of 10 ms: Digital filter 9 to 9.5 ms
Response Frequency
- (High-Speed Phase A and Phase B Input) Single phase: 100 kHz, phase difference: 50 kHz, 24 V ±10 %, Service 50 %
Output Specifications
Number of Relays
- R500 to R515 (16 points)
Output Mode
- Relay
Rated Load
- 250 V AC/30 V DC, 2 A
Common Point Mode
- 2 to 4 points/1 common
ON/OFF Response Time
- 10 ms or less
ON Resistance
- 50 mΩ or less
Minimum Applicable Load
- 100 µA/100 mVDC
Relay Life
- Electrical: 100000 cycles or more (20 cycles/minute), Mechanical: 20000000 cycles or more
Relay Replacement
- Impossible
Integrated Serial Port
Interface
- RS-232C standard
Connection
- Modular connector
RS-232C Transmission Specifications
- Transmission Speed
- 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
- Transmission Method
- Full duplex
- Data Format
- Start bit: 1 bit, Data bits: 7 bits, Stop bit: 1 bit, 2 bits
- Error Detection
- Parity: Even, Odd, None
- Transmission Distance
- 15 m (49.2')
- Number of Transmission Units
- 1
Indicator Lights
- SD (green), RD (red)
Internal Current Consumption
- 86 VA (VA values are calculated with a power factor of 30 %.)
Weight
- Approx. 660 g