Detectible Distance 5m, M12 Connector Cable, Class 2 Laser
- Code / Model:
- Manufacturer: Keyence
- Department: Connectors
- Category of products: Circular connectors
- Sub-category: Industrial circular connectors
- You've seen it before.: 1
Model
LR-TB5000C
Type
Cable with M12 Connector
Detectable Distance
60 to 5000 mm (2.36" to 196.85")
Spot Diameter
Variable (Use a spot diameter of 40 mm (1.57") or less)
Response Time
Selectable: 1 ms/10 ms/25 ms/100 ms/1000 ms
Light Source
Type
Red Laser (660 nm)
Laser Class
Class 2 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10 *2)
Mutual Interference Prevention Function
4 units (when using the mutual interference prevention function)
Timer
OFF/OFF Delay/ON Delay/Single Shot
Power Supply Voltage
20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS
Current Consumption
50 mA or less (no load) *3
I/O
Control Output
Selectable: Open Collector NPN/Open Collector PNP
30 VCD or less, 50 mA or less, Residual Voltage: 2 V or less, N.A./N.C. selectable *4 *5
Protection Circuit
Protection against reverse power supply connection, power surges, output overcurrent, reverse output connection, and output surges
Environmental Resistance
Degree of Protection
IP65/IP67 (IEC60529)
Ambient Light
Incandescent Lamp/Sunlight: 10,000 lux or less
Ambient Temperature
-20 to +55 °C (-4 to 131 °F) (No freezing)
Relative Humidity
35 to 85% HR (No condensation)
Vibration Resistance
10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions
Shock Resistance
1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material
Housing
Zinc Die-Casting (Nickel Plated)
Indicator and Button Cover
PES
Lens and Display Cover
PMMA (Scratch-resistant coating specifications)
Cable Bush
PBT
Cable
PVC
M12 Connector
TPE, PBT, Nickel Plated Brass
Accessories
- Instruction Manual
- Laser Warning and Explanatory Labels
Weight
Approx. 160 g
Notes
- *1 The visible distance range is from 50 to 5200.
- *2 FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50.
- *3 150 mA or less (with load)
- *4 You can select the I/O from the following combinations:
- Control Output × 2, Control Output + External Input
- Control Output + Analog Output (Only LR-TB5000/TB5000C/TB5000CL)
- External Input + Analog Output (Only LR-TB5000/TB5000C/TB5000CL)
- *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.
(For more details on the configuration method, refer to the instruction manual).