General purpose pneumatic pencil type head (low force measurement type)
- Code / Model:
- Manufacturer: Keyence
- Department: Hydraulic and pneumatic
- Category of products: Pneumatic sensors and switches
- Sub-category: Air conditioning systems
- You've seen it before.: 1
GT2-PA12L Specifications
This document outlines the specifications for the GT2-PA12L model.
System Information
- Detection System: Scale Shot System II, absolute type (no tracking errors)
Measurement Range and Resolution
- Measurement Range: 12 mm
- Resolution: 0.5 µm / 0.02 Mil
Accuracy and Force
- Indicated Accuracy: 2 µm / 0.08 Mil (P-P) *1
Measurement Force:
- Downward Mounting: 0.4 N *2
- Lateral Mounting: 0.35 N *2
- Upward Mounting: 0.3 N *2
Sampling and Fluid
- Sampling Cycle: 4 ms
- Fluid Used: Saubere, trockene Luft (Clean, dry air)
Indicators and Environmental Resistance
- Operation Indicator Light: Two-color LED (red, green)
- Environmental Resistance:
- Degree of Protection: -
- Pressure Resistance: 0.5 MPa
- Applied Pressure Range: 0.05 MPa to 0.07 MPa
- Ambient Temperature: 0 to +55 °C (32 to 131 °F) (No freezing)
- Relative Humidity: 35 to 85 % HR (No condensation)
- Vibration Resistance: 10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions
- Shock Resistance: 1,000 m/s2 *2 (IEC60068-2-27)
Materials
Main Housing: SUS 303, Status Indicator: PET, Head Relay Connector Cable: PUR, Relay Connector: PBT, Plunger: SUS430/SUS440C
Contact: SUS304, SUS440C *3
Cable and Weight
- Head Cable: Optional (connects to the relay connector)
- Weight: Approx. 35 g (excluding cable) *4
Notes
- *1 Value when ambient temperature is 20 °C (68 °F).
- *2 Representative value at the center of the measurement range. This is a representative value when using the GT2-PA12KL/PA12L with a pressure of 0.06 MPa. The measurement force varies depending on the pneumatic pressure used. For more details, see Table 1. No dust covers are used with the GT2-PA12KL/PA12L.
- *3 There are available contact options sold separately.
- *4 Including the relay connector.