Analog Unit Type 3-Point Terminal Block
- Code / Model:
- Manufacturer: Keyence
- Department: Test and measurement
- Category of products: Multi-meters and accessories
- Sub-category: Unclassified
- You've seen it before.: 1
Model
KV-N3AM
Conversion
A/D Conversion, D/A Conversion
Number of Points
A/D Conversion: 2 (single-ended), D/A Conversion: 1
Analog I/O Range and Resolution
Voltage
- -10 to +10 V
- A/D Conversion: 1/8000 2.5 mV, D/A Conversion: 1/8000 2.5 mV
- *1 0 to 10 V
- A/D Conversion: 1/4000 2.5 mV, D/A Conversion: 1/4000 2.5 mV
- *1 0 to 5 V
- A/D Conversion: 1/4000 1.25 mV, D/A Conversion: 1/4000 1.25 mV
- *1 1 to 5 V
- A/D Conversion: 1/3200 1.25 mV, D/A Conversion: 1/3200 1.25 mV
- *1
Current
- 0 to 20 mA
- A/D Conversion: 1/4000 5 µA, D/A Conversion: 1/4000 5 µA
- *1 4 to 20 mA
- A/D Conversion: 1/3200 5 µA, D/A Conversion: 1/3200 5 µA
- *1
Conversion Speed
80 µs/channel *2
Conversion Accuracy
Voltage
- Without Temperature Compensation
- A/D Conversion:
- ±0.3 % of F.E. (at 25 °C ±5°C / 77 °F ±9 °F)
- ±0.5 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- D/A Conversion:
- ±0.3 % of F.E. (at 25 °C ±5 °C / 77 °F ±9 °F)
- ±0.5 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- With Temperature Compensation
- A/D Conversion:
- ±0.3 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- D/A Conversion:
- ±0.3 % of F.E. (at 25 °C ±5 °C / 77 °F ±9 °F)
- ±0.5 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
Current
- Without Temperature Compensation
- A/D Conversion:
- ±0.4 % of F.E. (at 25 °C ±5 °C / 77 °F ±9 °F)
- ±0.6 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- D/A Conversion:
- ±0.3 % of F.E. (at 25 °C ±5 °C / 77 °F ±9 °F)
- ±0.5 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- With Temperature Compensation
- A/D Conversion:
- ±0.4 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
- D/A Conversion:
- ±0.3 % of F.E. (at 25 °C ±5 °C / 77 °F ±9 °F)
- ±0.5 % of F.E. (from 0 to 55 °C / 32 to 131 °F)
Input Resistance
- Voltage: A/D Conversion: 5 MΩ
- Current: A/D Conversion: 250 MΩ
Maximum Absolute Input
- Voltage: A/D Conversion: ±15 V
- Current: A/D Conversion: ±30 mA
Isolation Method
- Between Analog I/O and CPU: Isolated (photocoupler, transformer)
- A/D and D/A Conversion Unit:
- Between Input and Output Analogs: Not isolated
- Between Analog Input Channels: A/D Conversion: Not isolated
Minimum Load Resistance
Voltage: D/A Conversion: 1 kΩ
Maximum Load Resistance
Current: D/A Conversion: 600 kΩ
Special Functions
A/D Conversion
- Input Range Switching, Temperature Fluctuation Compensation Enable/Disable, Channel Skip, Scaling, Special Data Compensation, Peak/Valley Value Retention, Zero Clip, Zero Offset, Comparator, Averaging (Time Specified, Count Specified, Moving Average), Disconnect Detection
D/A Conversion
- Output Range Switching, Output Data Compensation, Scaling, Error Retention, Upper/Lower Limit Alarm, Output Limit, Channel Skip, PROG Mode Output
Internal Current Consumption
120 mA or less
Weight
200 g
*1 For information on the possible measurement range for out-of-range inputs, refer to the “A/D and D/A Conversion Table” in the KV-N3AM User Manual.
*2 When using temperature fluctuation compensation, a temperature fluctuation compensation time of 80 µs will be added, regardless of the number of channels used.