Keyence IL-065 Sensor Heads

Keyence IL-065 Sensor Heads

Model IL-065

Reference distance: 65 mm (2.56")

Measurement range: 55 to 105 mm (2.17" to 4.13")

Light source

  • Type: Red semiconductor laser, wavelength: 655 nm (visible light)
  • Laser class:
    • Class 2 (FDA (CDRH) Part1040.10)
    • Class 2 (IEC 60825-1)
  • Output: 560 μW

Spot diameter (at standard distance)

Approx. 550 × 1750 µm (21.65 x 68.9 Mil)

Performance

  • Linearity: ±0.1% of F.S. (55 to 75 mm (2.17" to 2.95"))
  • Repeatability: 2 µm (0.08 Mil)
  • Sampling cycle: 0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Environmental characteristics

  • Temperature characteristics: 0.06% of F.S./°C
  • Environmental resistance:
    • Enclosure rating: IP67
    • Operating ambient luminance: Incandescent lamp: 7500 lux
    • Operating temperature range: -10 to +50°C (14 to 122°F) (No condensation or freezing)
    • Operating ambient humidity: 35 to 85% RH (No condensation)
    • Vibration: 10 to 55 Hz Double amplitude 1.5 mm (0.06") XYZ each axis: 2 hours
    • Pollution degree: 3

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 75 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50.

*2 Value when measuring the KEYENCE standard target (white diffuse object).

*3 F.S. of each model is as follows. IL-030: ±5 mm (±0.20") IL-065: ±10 mm (±0.39") IL-100: ±20 mm (±0.79") IL-300: ±140 mm (±5.51") IL-600: ±400 mm±15.75".

*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms.

*5 Value when the sampling rate is set to 2 ms or 5 ms.


Products Related