Model
LV-N11CN
Type
1 Output
Emission
NPN
Cable/Connector
M8 Connector
Main Unit/Expansion
Main Unit
I/O
Control Outputs
1 Output
External Input
1 Input
Monitor Output
None
Response Time
80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1
Output Selection
Light-On (LIGHT-ON)/Dark-On (DARK-ON) (Selectable by switch)
Timer Function
- Timer Disabled (OFF)/Delay Timer Disabled (OFF)/Delay Timer Activated
- Single Shot Timer, Duration Selection: 1 ms to 9999 ms
- Maximum Error Against Set Value: ±10% max.
Control Output
Open Collector NPN 30 V, Residual Voltage 1 V or less (Output Current: 10 mA or less) / 2 V or less (Output Current: 10 to 100 mA)
(Independent) 1 output max: 100 mA or less, total 2 outputs: 100 mA or less
(Multiple Connections) 1 output maximum: 20 mA or less.
Monitor Output
-
External Input
Input Time 2 ms (ON)/20 ms (OFF) or more *2
Multiple Connections to Expansion Units
Up to a maximum of 17 units can be connected in total (the two-output model is considered as two units)
Protection Circuit
Reverse Polarity Protection, Overload Protection, Wave Absorber
Number of Interference Prevention Units
- Connected to a different unit other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
- Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA *3
Cover Size
Height 32.6 mm (1.28") × Width 9.8 mm (0.39") × Length 78.7 mm (3.1")
Rated Value
Power Supply Voltage
24 VCD (Operating Voltage 10 - 30 VCD (with fluctuation)), Ripple (P-P) 10% or less, Class 2 or LPS *4
Operating Condition
Power Consumption
- Normal: 830 mW or less (at 30 V . 30 mA at 24 V, 56 mA or less at 12 V) *5
- Eco Mode On: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V) *5
- Eco Full Mode: 550 mW or less (at 30 V . 21 mA at 24V, 40 mA or less at 12 V) *6
Ambient Resistance
Temperature
From -20 to +55 °C (-4 to +131 °F) (No Freezing) *7
Relative Humidity
35 to 85% HR (No Condensation)
Vibration Resistance
10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y and Z directions
Shock Resistance
500 m/s² , 3 times in each of the X, Y and Z directions
Material
- Cable: PVC
- Cover: Main Unit and Cover Material: Polycarbonate
Weight
Approx. 20 g
*Footnotes:*- 80 µs cannot be selected when LV-S31/S62/S63 is connected.
- The input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.
- The numbers are doubled when "DOUBLE" is selected.
- To connect more than 9 units, the voltage must be 20 V or more.
- Increases by 30 mW (1 mA) for high-speed mode.
- Increases by 15% when connected to LV-NH100/NH110/NH300. This does not include the power consumption of the load. The power consumption when expansion units are connected is the total consumption of each amplifier. Example: When a main unit (LV-N11N) is connected to two expansion units (LV-N12N) and these are used with LV-NH100 heads in HIGH SPEED mode. (1.15 x 860 mW x 1) + (1.15 x 860 mW x 2) = 2967 mW max.
- When used together, more than one unit, the ambient temperature varies with the conditions mentioned below. Install the units on the DIN rail with the mounting hardware and check that the output current is less than or equal to 20 mA for each unit. One or two additional units connected: from -20 to +55 °C (-4 to +131 °F); 3 to 10 additional units connected: from -20 to +50 °C (-4 to +122 °F); 11 to 16 additional units connected: from -20 to +45 °C (-4 to +113 °F). When using 2 outputs, one unit is counted as two units.