Detectable Distance 2m, M12 Connector Cable, Class 2 Laser

Detectable Distance 2m, M12 Connector Cable, Class 2 Laser

Model

LR-TB2000C

Type

Cable with M12 Connector

Detectable Distance

60 to 2000 mm (2.36" to 78.74")*1

Spot Diameter

Approx. 4 mm (0.16")

Response Time

Selectable: 1 ms/10 ms/25 ms/100 ms/1000 ms

Light Source

Type

Red Laser (660 nm)

Laser Class

Class 2 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)

Mutual Interference Prevention Function

4 units (when using the mutual interference prevention function)

Timer

OFF/OFF Delay/ON Delay/Single Shot

Power Supply Voltage

20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS

Current Consumption

45 mA or less (no load)*3

I/O

Control Output

Selectable: Open Collector NPN/Open Collector PNP

30 VCD or less, 50 mA or less, Residual Voltage: 2 V or less,

N.A./N.C. selectable*4 *5

Analog Output

-

Protection Circuit

Reverse Power Supply Connection Protection, Power Surge Protection, Output Overcurrent Protection, Reverse Output Connection Protection, Output Surge Protection

Environmental Resistance

Degree of Protection

IP65/IP67 (IEC60529)

Ambient Light

Incandescent Lamp/Sunlight: 10,000 lux or less

Ambient Temperature

-20 to +55 °C (-4 to 131 °F) (No Freezing)

Relative Humidity

35 to 85% HR (No Condensation)

Vibration Resistance

10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions

Shock Resistance

1,000 m/s²*2, 6 times in each of the X, Y, and Z directions

Material

Housing: Zinc Die-Casting (Nickel Plated), Indicator and Button Cover: PES,

Lens and Display Cover: PMMA (Scratch-Resistant Coating Specifications), Cable Bush: PBT,

Cable: PVC, M12 Connector: TPE, PBT, Nickel-Plated Brass

Accessories

Instruction Manual, Laser Warning and Explanatory Labels

Weight

Approx. 85 g

Notes

  • *1 The visible distance range is from 50 to 2200 mm.
  • *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50.
  • *3 145 mA or less (with load)
  • *4 You can select the I/O from the following combinations:
    • Control Output × 2, Control Output + External Input
    • Control Output + Analog Output (Only LR-TB5000/TB5000C/TB5000CL)
    • External Input + Analog Output (Only LR-TB5000/TB5000C/TB5000CL)

    (For more details on the configuration method, refer to the instruction manual).

  • *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.