KEYENCE CZ-V21AP
- Code / Model: CZ-V21AP
- Manufacturer: Keyence
- Department: Automation and control of processes
- Category of products: Industrial sensors
- Sub-category: Multifunctional sensors
- You've seen it before.: 1
CZ-V21AP Model
This document provides specifications for the CZ-V21AP model.
Main Unit/Expansion Unit
The main unit is a standalone device. Expansion units can be connected to increase functionality.
Response Time
- 200 μs (HIGH SPEED)
- 1 ms (FINE)
- 4 ms (TURBO)
- 8 ms (SUPER)
Output
The output type is PNP open-collector.
- 4 channels
- 30 VDC max.
- Up to 100 mA for one output
- Up to 200 mA in total of 4 outputs
- Residual voltage: 1.0 V max.
Protection Circuit
The CZ-V21AP includes protection features for reliable operation:
- Reverse-polarity protection
- Overcurrent protection
- Surge absorber
External tuning input, external bank switch input (C/C + I-mode), and external shift input (super I-mode) are also available.
Input time: 20 ms min.
Timer Function
The CZ-V21AP offers various timer functions for precise control:
- Timer OFF
- OFF-delay
- ON-delay
- One-shot
Timer time: 1 to 1000 ms adjustable (for each bank respectively)
Unit Expansion
Up to 3 expansion units can be connected to the main unit, resulting in a total of 4 units.
Number of Interference Prevention Units
- 0 for HIGH SPEED
- 2 for FINE/TURBO/SUPER
Rating
Power Voltage
24 VDC, Ripple (P-P): 10% max.
Current Consumption
Normal mode: 1.5 W (62.5 mA max.), Eco-mode: 1 W (42.0 mA max.)
Environmental Resistance
Operating Temperature Range
-10 to +55°C (14 to 131°F), No freezing
Vibration
10 to 55 Hz, 1.5 mm (0.06") double-amplitude in X, Y, and Z directions, 2 hours respectively
Material
Housing, cover: Polycarbonate
Accessories
- Mounting Fittings
Weight
Approx. 110 g
Important Notes
*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to the main unit of the FS-V20 Series. To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50°C (14 to 122°F). When 3 units are connected: -10 to +45°C (14 to 113°F).