KEYENCE CZ-V21AP

KEYENCE CZ-V21AP

CZ-V21AP Model

This document provides specifications for the CZ-V21AP model.

Main Unit/Expansion Unit

The main unit is a standalone device. Expansion units can be connected to increase functionality.

Response Time

  • 200 μs (HIGH SPEED)
  • 1 ms (FINE)
  • 4 ms (TURBO)
  • 8 ms (SUPER)

Output

The output type is PNP open-collector.

  • 4 channels
  • 30 VDC max.
  • Up to 100 mA for one output
  • Up to 200 mA in total of 4 outputs
  • Residual voltage: 1.0 V max.

Protection Circuit

The CZ-V21AP includes protection features for reliable operation:

  • Reverse-polarity protection
  • Overcurrent protection
  • Surge absorber

External tuning input, external bank switch input (C/C + I-mode), and external shift input (super I-mode) are also available.

Input time: 20 ms min.

Timer Function

The CZ-V21AP offers various timer functions for precise control:

  • Timer OFF
  • OFF-delay
  • ON-delay
  • One-shot

Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit Expansion

Up to 3 expansion units can be connected to the main unit, resulting in a total of 4 units.

Number of Interference Prevention Units

  • 0 for HIGH SPEED
  • 2 for FINE/TURBO/SUPER

Rating

Power Voltage

24 VDC, Ripple (P-P): 10% max.

Current Consumption

Normal mode: 1.5 W (62.5 mA max.), Eco-mode: 1 W (42.0 mA max.)

Environmental Resistance

Operating Temperature Range

-10 to +55°C (14 to 131°F), No freezing

Vibration

10 to 55 Hz, 1.5 mm (0.06") double-amplitude in X, Y, and Z directions, 2 hours respectively

Material

Housing, cover: Polycarbonate

Accessories

  • Mounting Fittings

Weight

Approx. 110 g

Important Notes

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to the main unit of the FS-V20 Series. To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.

*2 20 mA max. when several units are connected.

*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50°C (14 to 122°F). When 3 units are connected: -10 to +45°C (14 to 113°F).