FS-N12CP Model
Standard
1 output standard
Connector
M8
Emission
PNP
Unit Type
- Main unit/Expansion unit
Control Output
1 PNP open-collector 24 V; max. 1 output: 100 mA or less; total 2 outputs: 100 mA or less (use only)/20 mA or less (multiple connections); residual voltage 1 V or less
External Input
- 1
Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)
Response Time
50 μs (HIGH SPEED)/250 μs (FINE)/500 μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)
Multiple Connections to Expansion Units
Up to a total of 16 units can be connected (the two-output unit counts as two units)
Light Source
Red, 4-element LED
APC
Selectable ON/OFF (Factory parameter: OFF)
Number of Units with Interference Prevention
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA (When set to double, the number of interference-prevention units will be doubled.)
Classification
Supply Voltage
12 - 24 VCD ±10% fluctuation (P-P) 10% or less
Current Consumption
- Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)
- Eco On Mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)
- Eco Full Mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)
Ambient Resistance
- Ambient Luminosity: Incandescent lamp: 20000 lux or less; Sunlight: 30000 lux or less
- Operating Ambient Temperature: -20 to +55°C / -4 to 131°F (no freezing)
- Operating Ambient Humidity: 35 to 85% HR (no condensation)
Vibration Resistance
10 to 55 Hz composite amplitude 1.5 mm / 0.06", 2 hours for each axis X,Y,Z
Impact Resistance
500 m/s2, 3 times for each axis X,Y,Z
Housing Material
Main unit and expansion unit cover material: Polycarbonate
Weight
Approx. 22 g