Inclinometro Dual AXIS
Si vous souhaitez une demande de devis pour ce produit, veuillez cliquer sur le bouton suivant.
Demander des prixParameter Value Comment Range ±90° Dual axis sensor Accuracy, typ. 0.5° T= -40 °C – 85 °C Accuracy, typ. 0.15° T= 25 °C Resolution 0.01° Limited by CAN protocol Refresh rate 100 Hz Internal processing Startup time <1 s After power cycle Supply/excitation voltage 8 – 30 V Direct current (DC) stabilized Supply current, typ. <30 mA Typ. 20mA, peak 30mA during transmit Output x-axis and y-axis Linearized and temperature compensated angles in degree, reference is plane perpendicular to vector of gravity = earth surface Interface SAE J1939 CAN2.0B 250 kbps Source Address: - G-NSDOG2-200: 0xC2 (fix) - G-NSDOG2-207: 0xC0 (default); settable in the range of [0x80 – 0xF7] Connector AMP Superseal 1.5-Series, 4-pos. cap housing, TE Connectivity part-no. 282106-1 Requires 4-pos. plug housing, AMP Superseal 1.5-Series at connecting harness, TE Connectivity part-no. 282088-1 Cable 4 wire 0.25 mm2 , outer diameter Ø3.9 mm PUR, length incl. connector 400 mm, full temperature range, flexible Operation temperature range -40 °C – 85 °C Storage temperature range -40 °C – 85 °C Weight, typ. 60 g Dimensions 70.5 mm x 45 mm x 15 mm W x D x