Unique Unit Type Controller, PNP type
- Code / Model:
- Manufacturer: Keyence
- Department: Test and measurement
- Category of products: Multi-meters and accessories
- Sub-category: Unclassified
- You've seen it before.: 1
Model
LK-G3001PV
Type
Separated Type LK-G3001P/LK-GD500
Type
Single Unit Model
Head Compatibility
Compatible
Number of Connectable Sensors
Maximum of Two Heads
Display
- Minimum Display Unit: 0.01 µm
- Display Range: ±9999.99 mm to ±9999.99 µm (Selectable among six steps)
- Presentation Cycle: 10 times/sec.
Terminal Block
- Analog Output Voltage: ±10 V x 2 outputs, output impedance 100 Ω
- Current Analog Output: 4 to 20 mA x 2 outputs, maximum load resistance 350 Ω
- Timer Input: Input with voltage OUT1
- Reset Input
- Auto-Zero Input
- Remote Laser Interlock Input
- Voltage-Free Input
- Evaluation Output: PNP open-collector output for OUT1
- Alarm Output: PNP open-collector output for OUT1 (N.C.)
Expansion Connector
- Timer Input: Voltage input for OUT2
- Reset Input
- Auto-Zero Input
- Program Change Input: Voltage input x 3 inputs
- Laser-Off Input: Voltage input for Head A/Head B
- Evaluation Output: PNP open-collector output for OUT2
- Alarm Output: PNP open-collector output for OUT2 (N.C.)
Binary
- Binary Output: Measurement data output (21 bits)
- OUT1/OUT2 selectable
- PNP open-collector output
- Synchronization Output: PNP open-collector output
- Binary Selector Output: Binary selector input
- Voltage Input
RS-232C Interface
Output of measurement data and control I/O (selectable up to a baud rate of 115200 bit/s)
USB Interface
USB Revision 2.0, High Speed (USB1.1 compatible) compliant
Main Functions
- Simultaneous Measurement Function 2-OUT, Calculation Function, Average Calculation Function, Filter Function, Calibration Function, Measurement Function, Auto-Zero Function, Sampling Cycle Adjustment Function, Mutual Interference Prevention Function, Data Storage Function, 8 Program Memory Function, Eco Mode, ABLE Adjustment Function, Target Measurement Adjustment Function, ABLE Calibration Function, Transparent Object Measurement Surface Selection Function, Statistical Calculation Function, Software Connection Function, Configuration Support Function, Head Installation Selection Function, and others.
Rated Value
- Power Supply Voltage: 24 VCD ±10%, Ripple (P-P) 10% or less
Classification
- Maximum Current Consumption: When connecting one measuring head 500 mA or less / When connecting two measuring heads 600 mA or less
Environmental Resistance
- Ambient Temperature: 0 to +50 °C (32 to 122 °F)
- Relative Humidity: 35 to 85% HR (No condensation)
Weight
Approx. 480 g
*1 Features of PNP open-collector output: 50 mA Max. (30 V or less), Residual voltage: 1.0 V or less. *1 Features of voltage input; Accumulation rate:26.4 V, ON Voltage: 10.2 V, OFF current: 0.6 mA. Each circuit of the LK-G's input/output shares a common internal point. Make sure that no potential difference is generated between the common terminals due to potential differences between the cables or external devices. Refer to "Wiring Precautions" (page 2-4) for more information.