Sensor Amplifier Unit, for IV-G
- Code / Model:
- Manufacturer: Keyence
- Department: Automation and control of processes
- Category of products: Controllers, HMI Displays and IoT Gateways
- Sub-category: Controllers, PLCs and Automates
- You've seen it before.: 21
Model
IV-G10
Type
Main Unit
Tools
Type
- Shape Detection, Area
- Color Area
- Position Adjustment
Number
- Detection Tools: 16 tools
- Position Adjustment Tool: 1 tool
Recipe (Program) Settings
32 programs
Image History
Numbers:
- When using a color type head: 100 images
- When using a monochrome type head: 300 images
Condition
Only NG/All selectable
Analysis Information
OFF/Statistics/Histograms are switchable
- Statistics: Processing time (last value, MAX, MIN, PROM), number of OKs, number of NGs, number of shots, shooting errors, list of evaluation results per tool
- Histograms: Histogram, matching degree (last value, MAX, MIN, PROM), number of OKs, number of NGs
Other Functions
- HDR, High Gain, Color Filters
- Digital Zoom (2x, 4x)
- Brightness Correction, Tilt Correction, White Balance
- Mask Contour, Mask Area, Test Execution, Tool Auto-Adjustment, Input Monitor, Output Test, Safety Settings, Simulator, Mutual Interference Prevention, Total Evaluation Result Output, Direct Connection (2 units or more), List of Faulty Sensors, Fault Retention
Indicators
- ENC/ERR, OUT, DISP, STATUS, LINK/ACT
Input
Type
Non-voltage/Voltage input switchable
- For non-voltage input: ON Voltage 2 V or less, OFF Current 0.1 mA or less, ON Current 2 mA (short circuit)
- For voltage input: Nominal maximum input 26.4 V, ON Voltage 18 V or greater, OFF Current 0.2 mA or less, ON Current 2 mA (for 24 V)
Inputs
6 inputs (IN1 to IN6)
Function
- IN1: External Trigger, IN2 to IN6: Enable, assigning optional functions
- Assignable Functions: Program Change, Error Clear, Master Image External Recording, Main Unit/Expansion Unit Simultaneous Input
Output
Type
NPN/PNP open collector output is switchable, N.A./N.C. is switchable
- For NPN open collector output: Nominal maximum value 26.4 V 50 mA (20 mA if connected to an expansion unit [IV-G15]), remaining voltage 1.5 V or less
- For PNP open collector output: Nominal maximum value 26.4 V 50 mA (20 mA if connected to an expansion unit [IV-G15]), remaining voltage 2 V or less
Outputs
8 outputs (OUT1 to OUT8)
Function
- Enable, assigning optional functions
- Assignable Functions: Total Evaluation Result, EXECUTE, OCCUPIED, Error, Position Adjustment Result, Each Tool Evaluation Result, Each Tool Logic Operation Result, Main Unit/Expansion Unit Logical Output
Ethernet
Standard
100BASE-TX/10BASE-T
Connector
8-pin RJ-45 connector
Network Function
- FTP Client, EtherNet/IP™ , PROFINET
Rated Value
Power Supply Voltage
24 VCD ±10% (including ripple)
Current Consumption
0.8 A or less. 1.5 A or less when using an expansion unit (IV-G15) as well. (Excluding output load.)
Environmental Resistance
Ambient Temperature
0 to +50 °C 32 to 122 °F (No freezing)
Relative Humidity
35 to 85% HR (No condensation)
Material
Main Unit Housing: Polycarbonate
Weight
Approx. 150 g