SCHNEIDER - 18660

SCHNEIDER - 18660

  • Code / Model:
  • Manufacturer: Schneider Electric
  • Department:
  • Category of products:
  • Sub-category: Automation and control
  • You've seen it before.: 1
Principal
Product range Other, including:
Gamma The Commission shall adopt implementing acts.
Name of the product The Commission shall adopt delegated acts in accordance with Article 21 of this Regulation.
Type of product or component Automatic switch in miniature
Short name of the device Other, including:
Application of the device For current > 0,1 A
Number of poles 4P
number of protected poles 4
[In] Rated current 100 A at 40 °C
Type of network Continuous current
Air conditioning
firing unit technology Heat and electrical conductors
Curve code C. Other
Cutting capacity 20 kA Icu at <= 500 V DC according to Icu
10 kA Icu at 500 V AC 50/60 Hz according to Icu
20 kA Icu at 440 V AC 50/60 Hz according to Icu
25 kA Icu at 380...415 V AC 50/60 Hz according to Icu
50 kA Icu at 220...240 V AC 50/60 Hz according to Icu
Category of employment Category A according to EN> 50 A
Sectioning power Yes, it is in the range of En> 50 A
Other
Network frequency 50/60 Hz
[Ue] Nominal employment stress Other, of a kind used for the manufacture of goods or services
500 V AC 50/60 Hz
<= 500 V direct current
220...240 V AC 50/60 Hz
Other, of a kind used for the manufacture of goods
magnetic bonding limit 8 x pol
[Ics] power of cut in service 37,5 kA 75% according to Icu - 220...240 V AC 50/60 Hz
18,75 kA 75% according to Icu - 380...415 V AC 50/60 Hz
15 kA 75% according to Icu - 440 V AC 50/60 Hz
7.5 kA 75% according to Icu - 500 V AC 50/60 Hz
20 kA 100% according to Icu - <= 500 V DC
The following shall be added to the list of the following: 690 V AC 50/60 Hz according to Icu
[Uimp] Resistance to stress peaks 8 kV for Icu
contact position indicator Yes, I did.
Type of control Manual fire test
Handkerchief
Local signalling Indication of on/off
Shoot indicator
Type of assembly Other, including:
Fitting support The following shall be added to the list of the following:
Compliance with the distribution block and the comb type barrier No , it 's not .
9 mm steps 12
Height Other, of a thickness of not more than 10 mm
Other Other, of a thickness of not more than 10 mm
The depth 81 mm
weight of the product 0,96 kg
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Prepared for locking Locked
Description of the locking options Integrated candado
Connections - terminals Other, of a kind used for the manufacture of goods of heading 8102
Flexible tunnel type terminals10...50 mm2
length of cable peeled to connect terminals 20 mm
Other, of a kind used for the manufacture of goods 6 N.m.
protection against land leakage The following is the list of the following items:
Around
The rules Icu
The IP protection level The following information is provided:
Grade of protection IK The following information shall be provided:
Degree of pollution 3 to En> 50 A
Category of overvoltage IV
The following is a list of the countries of the European Union: 2 in accordance with IEC 60068-1
relative humidity 95% at 55 °C
Operating room temperature -30 to 70 degrees
Storage room temperature - 40 to 70 degrees

Products Related