LK-H022 Laser Displacement Sensor

Model

LK-H022

Mounting Method

Diffuse Reflective

Reference Distance

20mm / 0.787"

Measurement Range

±3 mm / ±0.12"

  • *1 Measurement range when the sampling cycle is 20 µs or more.

Light Source

  • Type: Semiconductor Red Laser
  • Wavelength: 655nm
  • Laser Class (JIS C6802): Class 2
  • Emission: 0.95mW
  • Spot Diameter (at Standard Distance): ø25 µm

Linearity

±0.02% of E.T. (E.T.= 6 mm / 0.24")

  • *2 This value is obtained when the KEYENCE standard object (diffuse white piece or, for the LK-H008/LK-H008W only, metallic piece with specular surface) is measured in normal measurement mode.

Repeatability

0.02 µm (0.01 µm)

  • *3 This value is obtained when the KEYENCE standard object (diffuse white piece or, for the LK-H008/LK-H008W only, metallic piece with specular surface) is measured at the reference distance with the average number of measurements set to 16384. The value in parentheses is a typical example of a measurement with the average number of measurements set to 65536 and the sampling cycle at 200 µs.

Sampling Cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 selectable levels)

Temperature Characteristics

0.01% of E.T./°C (E.T.= 6 mm / 0.24")

Environmental Resistance

  • Degree of Protection: IP67
  • Ambient Light: Incandescent lamp or fluorescent lamp: 10,000 lux max.
  • Ambient Temperature: 0 to +50 °C / 32 to 122 °F
    • *4 When the ambient temperature increases to 40 °C / 104 °F or more, mount it on a metal plate before use.
  • Relative Humidity: 35 to 85% HR (No condensation)
  • Vibration Resistance: 10 to 55 Hz, Double Amplitude 1.5 mm / 0.06", 2 hours in each of the X, Y and Z directions

Material

Stamped Aluminum

Weight

Approx. 230 g