Pinza amperimétrica PCE-CM 5

Pinza amperimétrica PCE-CM 5

  • Code / Model:
  • Manufacturer: PCE Instruments
  • Department:
  • Category of products:
  • Sub-category: Instruments and equipment
  • You've seen it before.: 1
Amp-pump with NCV measurement / Measurement of current up to 200 A AC /
Direct frequency measurement with the current clip / Immediate use / Easy handling
The ampere clamp is a multi-functional meter. The ampere clamp can measure current without contact up to 200 A AC. The range of measurement of the ampere clamp covers a wide sector. Thanks to the ampere clamp measuring without contact it is possible to make
Another feature of the amperimetric clamp is the NCV (Not Connected Voltage) measurement. With this function the amperimetric clamp tells you whether a cable has voltage or not. This function also does not require preparing the measurement. Both features of the amperimet
The amperimetric clamp integrates other useful functions such as resistance measurement and continuity testing. Continuity testing allows you to detect if a relay located in an electrical cabinet is completely closed. Thanks to the amperimetric clamp's rapid measurement frequency it is

- Inductive current measurement up to 200 A AC
- Voltage measurement with frequency meter
- Hold function to freeze value on screen
- Temperature measurement with thermoelectric
- Small and compact design
- Less internal resistance with the LowZ function


   
The following is the list of the parameters:  
Other power  
Rate Resolution adopted by the Council Accuracy
200 A 0,1 A ±(3,0 % + 3 digits)
Frequency range: 40 ... 400 Hz
Maximum input current: 200 A AC
   
Continuous current  
Rate Resolution adopted by the Council Accuracy
Other, of a kind used for the manufacture of goods 0,1 μA ±(1,0 % + 4 digits)
Other, not further worked than hot-rolled 1 μA ±(1,0 % + 4 digits)
The maximum input current: 1000 μA
   
Continuous voltage  
Rate Resolution adopted by the Council Accuracy
Other electrical equipment 0,1 mV ±(0,7 % + 3 digits)
6 V 0,001 V ±(0,7 % + 3 digits)
60 V 0,01 V ±(0,7 % + 3 digits)
Other electrical equipment 0,1 V ±(0,7 % + 3 digits)
The input impedance shall be:
The maximum input voltage shall be 600 V DC AC rms.
     
Alternating voltage  
Rate Resolution adopted by the Council Accuracy
6 V 0,001 V ±(0,8% + 3 digits)
60 V 0,01 V ±(0,8% + 3 digits)
Other electrical equipment 0,1 V ±(0,8% + 3 digits)
The input impedance shall be:
The maximum input voltage shall be 600 V DC AC rms.
Frequency range: 40 ... 400 Hz
 
LowZ AC/DC  
Rate Resolution adopted by the Council Accuracy
Other electrical equipment 0,1 V ±(2,0 % + 3 digits)
The input impedance shall be:
The maximum input voltage shall be 600 V DC AC rmsS.
Frequency range: 40 ... 400 Hz
     
The resistance  
Rate Resolution adopted by the Council Accuracy
600 Ω 0,1 Ω ±(0,8% + 3 digits)
6 kΩ 0,001 kΩ ±(0,8% + 3 digits)
Other, of a kind used for the manufacture of goods 0,01 kΩ ±(0,8% + 3 digits)
Other, of a kind used for the manufacture of goods 0,1 kΩ ±(0,8% + 3 digits)
6 MΩ 0,001 MΩ ±(1,2% + 3 digits)
60 MΩ 0,1 MΩ ±(1,2% + 3 digits)
Test voltage (open circuit): 0,4 V
Protection against overvoltage: 250 V AC/DC rms
 
Continuity test  
Rate Resolution adopted by the Council Accuracy
- What ? 0,1 Ω - What ?
Protection against overvoltage: 250 V AC/DC rms
Signal tone in < 50 Ω
     
Test of diodes  
Rate Resolution adopted by the Council Accuracy
- What ? 0,001 V - What ?
Protection against overvoltage: 250 V AC/DC rms
The following shall be added to the list of the following:
The following shall be added to the list of the following:
     
Capacity  
Rate Resolution adopted by the Council Accuracy
Other, not further worked than hot-rolled 0,01 nF ±(4,0 % + 5 digits)
Other, not less than €1 0,1 nF ±(4,0 % + 5 digits)
Other, not further worked than hot-rolled 0,001 μF ±(4,0 % + 5 digits)
Other, of a thickness of not more than 0,15 mm 0,01 μF ±(4,0 % + 5 digits)
Other, of a thickness of not more than 0,9 mm 0,1 μF ±(4,0 % + 5 digits)
The following table shows the following: 1 μF ±(4,0 % + 5 digits)
Other, not further worked than hot-rolled 0,01 mF ±(4,0 % + 5 digits)
Protection against overvoltage: 250 V AC/DC rms
     
The temperature (type K)  
Rate Resolution adopted by the Council Accuracy
-20 ... 0 °C 1 °C ±(3,0 % + 2 digits)
1 ... 400 °C 1 °C ±(2,0 % + 2 digits)
-4 ... 32 °F 1 °F ±(3,0 % + 4 digits)
33 ... 752 °F 1 °F ±(2,0 % + 4 digits)
Protection against overvoltage: 250 V AC/DC rms
     
Frequency (with current pinch)  
Rate Resolution adopted by the Council Accuracy
The frequency of the sound 0,01 Hz ±(1,5% + 5 digits)
The frequency of the sound is: 0,1 Hz ±(1,5% + 5 digits)
Other, of a kind used for the manufacture of goods Other, of a kind used for the manufacture of goods For reference only
Frequency range: 10 Hz to 1 kHz
The maximum input voltage shall be 200 A AC rms.
Input range: > 60 A AC rms (increases the input current, also increases the frequency)
     
Frequency (voltage measurement)  
Rate Resolution adopted by the Council Accuracy
The frequency of the sound 0,01 Hz ±(1,5% + 5 digits)
The frequency of the sound is: 0,1 Hz ±(1,5% + 5 digits)
The frequency of the signal shall be: Other, of a kind used for the manufacture of goods ±(1,5% + 5 digits)
Other, of a kind used for the manufacture of goods Other, of a kind used for the manufacture of goods For reference only
Frequency range: 10 Hz ... 10 kHz
     
Frequency (direct measurement)  
Rate Resolution adopted by the Council Accuracy
The frequency of the sound 0,01 Hz ±(0,3 % + 5 digits)
The frequency of the sound is: 0,1 Hz ±(0,3 % + 5 digits)
The frequency of the signal shall be: 1 Hz ±(0,3 % + 5 digits)
Other power generators Other, of a kind used for the manufacture of goods ±(0,3 % + 5 digits)
Other power units Other, not further worked than hot-rolled ±(0,3 % + 5 digits)
Other power supplies 1 kHz ±(0,3 % + 5 digits)
The frequency of the transmission shall be: 0,01 MHz ±(0,3 % + 5 digits)
     
The frequency of the signal shall be:
The input impedance shall be:
Input range: >0,2 V AC rms (increases the input voltage, also increases the frequency)
The maximum input voltage shall be 250 V AC rms.
 
Working cycle  
Rate Resolution adopted by the Council Accuracy
5 ... 95 percent 0,1% ± 0,3%
     
Other specifications  
Selection of range Automatic and manual
Maximum working height 2000 m
Screen LCD
Maximum value on screen 5999 of the following:
Upper overrange The display indicates "OL"
Lower overrange The display indicates "-OL"
Measurement quota 3 measurements per second
Automatically disconnected After 15 minutes of inactivity
Food 1 x 9 V battery
Operating conditions 0 ... 40 °C
Storage conditions -10 ... 50 °C
Dimension Other, of a thickness of not more than 10 mm
Weight Approximately 265 g (including pile)
   


Products Related