Easy-to-use dew point meter with laser pointer / K-type probe input / Measurement of surface temperature, ambient temperature and humidity, dew point
The dew point meter has a 13:1 optical range, which allows measuring the surface temperature from a certain distance. It also measures the ambient temperature and humidity. The advantages of this dew point meter are its easy handling and its red laser pointer.
The dew point meter is multifunctional. The integrated flashlight enables the point where you want to measure to be illuminated when in dark places. Thanks to the individual settings of the dew point meter it can measure different types of temperatures and also humidity. It can adjust the emissiv

- Quick measurement sequence
- Adjustable emission levels: 0,1 and 1,0
- Automatically disconnected
- Laser pointer
- Selectable unit between °C and °F
- Different types of adjustment
- Batch fed
- Robust and compact construction
- UV leak detection function

The following is the list of the parameters: Infrared
Rate -50 ... 550 °C
Resolution adopted by the Council Other, of a kind used for the manufacture of goods
  Other, of a kind used for the manufacture of goods
Accuracy -50 ... 0 oC: ± 3 oC
  > 0 °C: ± 1,5 % or ± 2,0
  the upper value applicable
   
The following is the list of the parameters: Type K
Rate -50 to 850 oC
Resolution adopted by the Council Other, of a kind used for the manufacture of goods
  Other, of a kind used for the manufacture of goods
Accuracy ± 1,5 % or ± 1,5 °C
  the upper value applicable
   
The following is the list of the parameters: Air temperature
Rate -20 ... 60 oC
Resolution adopted by the Council The following conditions shall apply:
Accuracy 0 to 40 oC: ± 1,0 oC
  Other ranges: ± 2 °C
   
The following is the list of the parameters: Humidity of the air
Rate 0 ... 100% H.R.
Resolution adopted by the Council 1 %
Accuracy 35 ... 75% H.r.:
  ± 3,0 % H.r.
  Other ranges: ± 5% H.r.
   
The following is the list of the parameters: Roost point
Rate -20 ... 60 oC
Resolution adopted by the Council The following conditions shall apply:
Accuracy 25 oC , 40 ... 80% H.r.: ± 1,5 oC
   
The following is the list of the parameters: Temperature of the wet bulb
Rate -20 ... 60 degrees
Resolution adopted by the Council The following conditions shall apply:
Accuracy The following conditions shall apply:
   
Degree of emissivity Adjustable 0,1 ... 1,0
Optics 13: 1
Response time Other, of a kind used for the manufacture of goods
Spectral sensitivity 8 ... 14 um
Laser Other, of a kind used for the manufacture of electrical equipment
Automatically disconnected After 1 minute of inactivity
Operating conditions 0 ... 50 oC / ≤ 95% H.r.
Storage conditions -20 ... 70 oC / ≤ 80 % H.r.
Food 9 V battery
Weight Approximately 130 g