Medidor de temperatura PCE-ILD 10
- Code / Model:
- Manufacturer: PCE Instruments
- Department:
- Category of products:
- Sub-category: Instruments and equipment
- You've seen it before.: 1
Hand-held temperature gauge with limit value adjustment / Range: -50 ... 500 °C / Optics 12:1 /
The measurement rate is 2 Hz / Circular laser pointer / Robust case /
The following information is provided by the manufacturer:
The measurement rate is 2 Hz / Circular laser pointer / Robust case /
The following information is provided by the manufacturer:
The hand temperature meter measures in a range between -50 ... +500 oC and has an emission degree adjustment between 0.10 ... 1.00. In addition to indicating the current value, it can also display the maximum, minimum, average and differential value. Thanks to this it can use the hand temperature meter
To check the temperature, you can adjust different alarm limit values in this hand temperature meter.
In addition to measuring temperature, the handheld temperature meter has two lighting rings with 5 LEDs each. The lighting ring with 5 blue LEDs serves to detect leaks for example in climatological installations that integrate a contrast medium. The ring with 5 white LEDs allows
To check the temperature, you can adjust different alarm limit values in this hand temperature meter.
In addition to measuring temperature, the handheld temperature meter has two lighting rings with 5 LEDs each. The lighting ring with 5 blue LEDs serves to detect leaks for example in climatological installations that integrate a contrast medium. The ring with 5 white LEDs allows
- Range: -50 ... 500 °C
- Rapid measurement rate of 2 Hz
- White and blue LED lighting ring
- Optically 12:1
- Circular laser pointer
- UV leak detection function
- Optional: ISO calibration certificate
- Rapid measurement rate of 2 Hz
- White and blue LED lighting ring
- Optically 12:1
- Circular laser pointer
- UV leak detection function
- Optional: ISO calibration certificate
| Rate | -50 ... 500 °C (-58 ... 932 °F) | |
| Resolution adopted by the Council | The following conditions shall apply: | |
| Accuracy | The following conditions shall apply: ± 2 % or ± 2 °C (± 3,6 °F) | -50 to 20 °C (-58 to 68 °F) The following table shows the following: |
| Repeatability | The following conditions shall apply: | |
| Optics | 12:1 | |
| Emissions | 0,10 ... 1,00 | |
| Measurement quota | 2 Hz | |
| Spectral range | 8 ... 14 μm | |
| Over-ranking indication | - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - | |
| Power output | Other heat exchangers | |
| Wavelength | 630 ... 670 nm | |
| Laser class | 2 | |
| Lighting ring | 5 x white LED 5 x LEDs blue | |
| Food | 2 x 1.5 V Pilad, type AA | |
| Operating conditions | 0 ... 50 °C (32 ... 122 °F) 10 ... 90% H.r. without condensation | |
| Storage conditions | -10 ... 60 °C (14 ... 140 °F) 10 ... 90% H.r. without condensation | |
| Dimension | Other, of a thickness of not more than 10 mm | |
| Weight | 329 g (including stack) | |