Medidor de oxígeno PCE-PHD 1-O2
- Code / Model:
- Manufacturer: PCE Instruments
- Department:
- Category of products:
- Sub-category: Instruments and equipment
- You've seen it before.: 1
The test chemical shall be used to determine the concentration of the product.
SD memory card (1 ... 16 GB), values are stored in Excel format /
Large screen / RS-232 interface and optional software for real-time data transmission
SD memory card (1 ... 16 GB), values are stored in Excel format /
Large screen / RS-232 interface and optional software for real-time data transmission
The PCE-PHD 1-O2 oxygen meter is actually a multi-capacity apparatus for water quality inspection.
A calibration as well as an automatic temperature compensation guarantee high accuracy even with very variable temperatures to measure. As accessories are available different probes. All values can be stored directly on an SD card (1...16 GB) in Excel format, or be transferred via the RS-232
A calibration as well as an automatic temperature compensation guarantee high accuracy even with very variable temperatures to measure. As accessories are available different probes. All values can be stored directly on an SD card (1...16 GB) in Excel format, or be transferred via the RS-232
- Real-time recorder
- SD memory card (1 ... 16 GB)
- SD card record as Excel file (no software is needed for evaluation)
- RS-232 interface
- Measures pH, Redox, conductivity, salinity (optional)
- High precision
- Low battery status indication
- Large LCD screen
- Adjustable measurement ratio
- Easy to handle
- A sturdy shell
- Automatically calibrated
- Manual or automatic temperature compensation
- BNC connector
- Suitable for laboratory and on-site measurements
- SD memory card (1 ... 16 GB)
- SD card record as Excel file (no software is needed for evaluation)
- RS-232 interface
- Measures pH, Redox, conductivity, salinity (optional)
- High precision
- Low battery status indication
- Large LCD screen
- Adjustable measurement ratio
- Easy to handle
- A sturdy shell
- Automatically calibrated
- Manual or automatic temperature compensation
- BNC connector
- Suitable for laboratory and on-site measurements
| Measurement of oxygen | |
| Measurement range | 0 ... 20 mg/l (in water) 0 ... 100% (in air) 0 ... 50 °C |
| Resolution adopted by the Council | 0,1 mg/l 0,1% The following conditions shall apply: |
| Accuracy | The following is the list of the products used: ± 0,7% The following conditions shall apply: |
| Calibration | In the air |
| The following table shows the calculation of the total amount of the exposure: | Automatically (0 ... 50 °C) |
| General specifications | |
| Measurement quota | 1 second to 9 hours |
| Screen | LCD 52 x 38 mm |
| Memory | SD memory card (1 ... 16 GB) |
| Interface | Other, of a kind used for the manufacture of goods |
| Software | Available as an accessory (optional) |
| Food | 6 x 1.5 V AA batteries / 9 V network adapter (optional) |
| Environmental conditions | 0 ... +50 °C / < 85 % H.r. |
| Dimension | Other, of a thickness of not more than 10 mm |
| Weight | 490 g |