Medidor de gas PCE-GA 12

Medidor de gas PCE-GA 12

  • Code / Model:
  • Manufacturer: PCE Instruments
  • Department:
  • Category of products:
  • Sub-category: Instruments and equipment
  • You've seen it before.: 1
Gas meter for combustible gases / Rechargeable accumulator / Acoustic alarm /
400 mm semi-rigid probe / Duration of probe: approximately 5 years / Vibration alarm / Range: up to 10000 ppm / Power by accumulator and power grid
The fuel gas meter is a mobile, easy-to-use device. This gas meter measures fuel gases and generates a sound and vibration alarm when detecting flammable gas. Thanks to the semi-rigid probe of the fuel gas meter it is possible to orient the sensor to virtually any position
The fuel gas meter is therefore an ideal tool for detecting the presence or leakage of gases (system checking in factory inspection, checking engines and pipelines or gas pipeline).

- 85 dB sound alarm
- Rechargeable battery for mobile use
- Automatically calibrated
- Range: up to 10000 ppm
- Flue gas detection
- Duration of probe: approximately 5 years
- Vibration alarm
- Interchangeable probe


Detectable gasesOther, of a thickness of not more than 0,01 mm
 Other, of a thickness of not more than 10 mm
 Gasoline
 Other
 Other, of a thickness of not more than 10 mm
 Other, of a thickness of not more than 10 mm
 Formaldehyde
 Hexane
 Isobutan (methylpropano)
 Other methane
 Other, of a kind used for the manufacture of goods
 Other, of a kind used for the manufacture of goods
 Hydrogen sulphide
 Other
 Hydrogen
And the compounds in which these gases are present
Measurement rangeLow concentration: 0 to 1000 ppm
(for methane only)High concentration: 0 to 10000 ppm
% of the total0 ... 20%LEL
Sounding alarmThe sound volume: 85 dB
Sensitivity< 10 ppm (for methane only)
Measurement interval< 2 seconds
ScreenLCD with bar chart
CalibrationAutomated
Warming time40 seconds
FoodLi-ion polymer accumulator 18500 3,7 V
Other electrical equipmentInput: 100 ... 240 V, 50/60 Hz, 0,2 A
 Output: 5 V, 1 A
Automatically disconnectedWhen the battery capacity is low
 After 10 minutes of inactivity
The probe 
- The guy.Semi-rigid
- LengthOther, of a thickness of not more than 500 mm
- Head diameterOther, of a thickness of not more than 10 mm
Duration of the sensorApproximately 5 years (interchangeable sensor)
The probeSemi-rigid 400 mm / 16 "
WeightApproximately 430 g
  