Medidor de estrés térmico PCE-WB 20SD

Medidor de estrés térmico PCE-WB 20SD

  • Code / Model:
  • Manufacturer: PCE Instruments
  • Department:
  • Category of products:
  • Sub-category: Instruments and equipment
  • You've seen it before.: 1
Measurement of heat stress with data log / SD card memory /
WBGT measurement (internal and external), black balloon temperature, humidity, air temperature, dew point temperature, wet bulb temperature
The thermal stress meter measures the indoor and outdoor WBGT value, black balloon temperature, humidity, air temperature, humid bulb temperature, and dew point temperature. The thermal stress meter is designed for an objective assessment of working conditions in extreme weather conditions. In the industrial

- Large LCD graphics display
- Real time indication
- Integrated data logger
- Acoustic alarm
- H.R. in % and calculation of dew point
- SD memory card

Units of measureWBGT
The following table shows the results of the calculation of the total emission of the product:
Air temperature (TA)
The temperature of the wet bulb (WB)
Moisture
Temperature of the dew point
WBGT
Measurement rangeInterior: 0 ... +59 oC
External: 0 ... +56 oC
The internal precisionThe following conditions shall apply:
± 1,5 °C (other temperature ranges)
External precisionThe following conditions shall apply:
± 2 °C (other temperature ranges)
Air temperature (TA)
Measurement range0 ... +50 °C
Resolution adopted by the CouncilThe following conditions shall apply:
AccuracyThe following conditions shall apply:
Temperature of black balloon
Measurement range0 ... +80 °C
Resolution adopted by the CouncilThe following conditions shall apply:
AccuracyThe following conditions shall apply:
Moisture
Measurement range5 ... 95% H.r.
Resolution adopted by the Council0,1% H.r.
Accuracy> 70% H.r.: ± (3% of the measured value + 1 % H.r.)
The following is the list of the products of the product:
Temperature of dew point
Measurement range- 25,3 ... + 48,9 °C
Resolution adopted by the CouncilThe following conditions shall apply:
Humid bulb temperature
Measurement range- 21,6 ... +50 °C
Resolution adopted by the CouncilThe following conditions shall apply:
 
General technical specifications 
The following formulae are used:Interior / exterior and without sunlight:
The following is the list of the following:
Exterior and sun:
The following is the list of the following:
The data storage timeAutomatic: every 1 ... 3600 s
Manual: every time the button is pressed
Memory cardSD memory card 1 ... 16 GB
PortOther electrical equipment
ScreenLCD with background lighting (52 x 38 mm)
Operating temperature0... +50 °C
Environmental relative humidity< 85% H.r.
Food6 x 1.5 V AA batteries
ConsumptionDC 14 mA in normal operation
DC 37 mA in case of data storage and off-screen background lighting
Weight489 g
DimensionApparatus: 177 x 68 x 445 mm
The sphere: Ø 75 mm