Medidor de conductividad PCE-PWT 10
- Code / Model:
- Manufacturer: PCE Instruments
- Department:
- Category of products:
- Sub-category: Instruments and equipment
- You've seen it before.: 1
The following conditions shall apply:
Pocket-format conductivity meter / For purified water / Measure low range 0 to 20 μS/cm / Measurement of salt content /
Temperature compensation up to +60 oC
Pocket-format conductivity meter / For purified water / Measure low range 0 to 20 μS/cm / Measurement of salt content /
Temperature compensation up to +60 oC
The conductivity meter PCE-PWT 10 is an ideal solution for checking the conductivity of purified water. This conductivity meter is a compact device that integrates a temperature sensor for optimal temperature compensation.
This tester also allows for the precise determination of the salt content in liquids. The conductivity meter PCE-PWT 10 has an automatic temperature compensation in the range 0 to 60 oC. The conductivity meter integrates a 3-point calibration.
This tester also allows for the precise determination of the salt content in liquids. The conductivity meter PCE-PWT 10 has an automatic temperature compensation in the range 0 to 60 oC. The conductivity meter integrates a 3-point calibration.
- Low measurement range 0 to 20 μS/cm
- Compact construction
- Automatic temperature compensation
- Measurement of salt content
- Internal calibration of 3 points
- Interchangeable electrode
- Compact construction
- Automatic temperature compensation
- Measurement of salt content
- Internal calibration of 3 points
- Interchangeable electrode
| Technical specifications | |
| Conductance range | 0 ... 20 μS/cm 0 ... 200 μS/cm 0 ... 2000 μS/cm 0 ... 20,00 mS/cm |
| Resolution adopted by the Council | 0,01 / 0,1 / 1 |
| Accuracy | ± 1% of the scale fund |
| Number of calibration points | 1 ... 3 |
| Calibration points | Other, of a thickness of not more than 0,01 mm Other, of a thickness of not more than 10 mm The following table shows the following: |
| Range of salt content | 0,00 ... 10,00 ppt |
| Resolution adopted by the Council | 0,01 ppt |
| Accuracy | ± 1% of the scale fund |
| The temperature range | 0 ... 60 °C |
| Resolution adopted by the Council | The following conditions shall apply: |
| Accuracy | ± 1 °C |
| The temperature clearance range | 0 ... 60 °C |
| The temperature coefficient | 2 % / °C |
| Cell constant | K = 1 |
| Normal temperature of the medium | 25 °C |
| The HOLD function | Pressing a key |
| Automatically disconnected | After 8 minutes of inactivity |
| Reset | The ability to restore to factory values |
| Food | 2 x 1.5 V batteries, of type AAA |
| Operating time | About 200 hours |
| Dimension | Other, of a width of not more than 300 mm |
| Weight | Approximately 100 g |