Keyence LK-G82 laser sensor
- Code / Model:
- Manufacturer: Keyence
- Department: Test and measurement
- Category of products: Linear measurement
- Sub-category: Unclassified
- You've seen it before.: 33
LK-G82 Model
Reference Distance
80 mm 3.15" (Diffuse Reflection), 75.2 mm 2.96" (Specular Reflection)
Measurement Range
±15 mm ±0.59" (Diffuse Reflection), ±14 mm ±0.55" (Specular Reflection)
Light Source
Type
Red semiconductor laser
Wavelength
655 nm (visible light)
Laser Class
Class II (FDA (CDRH) Part 1040.10), Class 2 (IEC 60825-1)
Control Output
0.95 mW maximum
Spot Diameter (at Standard Distance)
Approx. ø70 μm ø2.73 Mil
Linearity
±0.05% of E.T. (E.T.= ±15 mm ±0.59") *1
Repeatability
0.2 µm *2, 0.000008" *3
Sampling Cycle
20/50/100/200/500/1,000 μs (Selectable from 6 levels)
LED Display
- Near the center of measurement: Green lights
- Within the measurement area: Orange lights
- Outside the measurement area: Orange flashing
Temperature Characteristics
0.01% of E.T./°C (E.T.= ±15 mm ±0.59")
Environmental Resistance
Protection Grade
IP67 (IEC60529)
Operating Ambient Temperature
0 to 50°C 32 to 122°F
Operating Ambient Humidity
35 to 85% HR (no condensation)
Ambient Illumination
Incandescent lamp or fluorescent lamp: 10,000 lux max.
Vibration
10 to 55 Hz, double amplitude 1.5 mm 0.06"; two hours in each direction of X, Y, and Z
Material
Stamped aluminum
Weight
Approx. 380 g (including cable)
*1 This value was taken by measuring a KEYENCE standard object (ceramic) in standard mode.
*2 Consult your nearest KEYENCE agent about the Type Class IIIa with increased resolution.
*3 These values were taken by measuring a KEYENCE standard object (SUS) at a reference distance and with the average number of measurements set to 4096