Model

LR-WF10

Type

Fiber type

Cable Type

  • 2 m (6.6')

Distance Detection

Detection of distance and minimum point diameter based on the attached fiber head.

Minimum Point Diameter

Refer to specifications.

Response Time

250 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable

  • *1
  • *2

Light Source

White LED

Mutual Interference Reduction Function

Up to 2 units when alternating frequencies are set.

Timer

  • OFF
  • Delay ON
  • Delay OFF
  • Single Shot

Power Source

Voltage Supply

10 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS

Current Consumption

50 mA or less (no load) at 24 VCD;

90 mA or less (no load) at 12 VCD

  • *3

I/O

Control Output

Selectable NPN/PNP open collector, 30 VCD or less, 50 mA or less, remaining voltage: 2 V or less, N.A./N.C. selectable

  • *4

External Input

Selectable laser emission start/stop, Short-circuit current: 1 mA or less for NPN/2 mA or less for PNP

For applied voltage, refer to the connection diagrams in the instruction manual.

For input times, refer to the timing table in the instruction manual.

  • *4

Protection Circuit

Protection against reverse power connection, power surges, output overcurrent, output surges, and reverse output connection.

Environmental Resistance

Degree of Protection

IP65 (IEC60529)

  • *5
  • *6

Ambient Light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient Temperature

-20 to +45 °C (-4 to +113 °F) (No freezing)

Relative Humidity

35 to 85% HR (No condensation)

Vibration Resistance

10 to 55 Hz, Double amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions

Shock Resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

  • Housing: Die-cast zinc (nickel-plated chrome)
  • Indicator Cover: PPSU
  • Buttons: PES
  • Display: PMMA (scratch-resistant coating)
  • Cable Ferrule: PBT
  • Cable: PVC
  • Fiber Locking Mount: PBT, NBR, Silicone Rubber, SUS304, SUSXM7
  • Adapter: PBT

Weight

Approx. 150 g (including cable)

*Footnotes:*
  • *1 When alternating frequencies are set, the response time increases by approx. 20%.
  • *2 When using IO-Link communication, if the response time is set to 1 ms or more, it becomes approx. 10% slower.
  • *3 160 mA or less (at 10 V, with load)
  • *4 IO-Link: Compatible with Specification v.1.1/COM2 (38.4 kbps). The installation file can be downloaded from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.
  • *5 When using the following small diameter fiber units (cable diameter is ø1.3 mm / ø0.05" or ø1.0 mm / ø0.04"), the IP65 rating cannot be met (FU-4F/66/91/93/43/63/63T etc.). When using any of the small diameter fiber units, except for the above, IP65 applies.
  • *6 In any of the following cases, the IP65 protection rating cannot be met. When the waterproof adapter A/B is not used at the time of installation of a small diameter fiber unit.