Detector de fallas PCE-FD 20

Detector de fallas PCE-FD 20

  • Code / Model:
  • Manufacturer: PCE Instruments
  • Department:
  • Category of products:
  • Sub-category: Instruments and equipment
  • You've seen it before.: 1
Ultrasonic failure detector for material testing / Battery or power supply / Includes two probes: 45° and 90° /
Connecting cable of 1,5 m
The PCE-FD 20 fault detector is used for material testing. One of the fields of use of the fault detector is to check whether the working materials have cracks, fissures, recoveries, etc. The fault detector is also suitable for testing welding joints. Ultr
The different probes send ultrasonic waves through the material. One of the probes has the feature of sending the wave at an angle of 90o, while the other does so at an angle of 45o. Once the ultrasonic wave is sent, it can determine the thickness of the material,

- Geometry of the probes: 45° and 90°
- Light weight
- Battery or power grid
- Cable length of the probe: 1.5 m
- Big backlit screen
- USB interface .

Technical specifications

Frequency range

1 ... 10 MHz

Duration of the scan

6 ... 1000 μm

Speed of ultrasound

1000 ... 9999 m/s

Time interval measurement error

Other, of a kind used for the manufacture of goods

Maximum measurement error of the amplitude signal at the receiver input in a range 0 to 110 dB

Other, of a kind used for the manufacture of goods

Amplification range

The maximum value of the product

Average of material checks

1 ... 16

Number of checkpoints
(variable time amplification)

15 Other

Time from pulse excitation to load

0,0 ... 0,5 μs

Pulse excitation range up to 50 Ohmios charge

Other materials of heading 83.0

Operating frequency of the receiver at -3 dB

1 ... 10 MHz

The width deviation in the input signal in the range of 10 to 100 % of the screen size

Other, of a kind used for the manufacture of goods

Scanning

1 ... 1000 μs

Delayed scan

0 ... 2000 μs

Measurement range of the time interval

0 ... 1000 μs

Late probe

0 ... 15 μs

Automatic notification in case of failure

Other, of a kind used for the manufacture of goods

Adjustment of the measurement range of the variable time amplification

0 ... 2000 μs

Adjustment of the variable time amplification limit values

0 ... 100%

The following information shall be provided:

Semi-positive, radio mode

Dimensions (width x height x depth)

80 x 162 x 35 mm

Screen dimensions

48 x 74 mm

Food

100 ... 250 V AC
3 x AA batteries of 1,5 V

Weight

250 g (without batteries)