Model
LR-TB2000
Type
Cable
Detectable Distance
60 to 2000 mm (2.36" to 78.74")*1
Spot Diameter
Approx. 4 mm (0.16")
Response Time
1 ms/10 ms/25 ms/100 ms/1000 ms selectable
Light Source
Type
Red Laser (660 nm)
Laser Class
Class 2 Laser Product (IEC60825-1, FDA(CDRH) Part1040.10*2)
Mutual Interference Prevention Function
4 units (when using the mutual interference prevention function)
Timer
- OFF
- Delay OFF
- Delay ON
- Single Shot
Power Supply Voltage
20 to 30 VCD, including 10% ripple (P-P), Class 2 or LPS
Current Consumption
45 mA or less (no load)*3
I/O
Control Output
Open Collector NPN/Open Collector PNP selectable
30 VCD or less, 50 mA or less, Residual Voltage: 2 V or less,
N.A./N.C. selectable*4 *5
Analog Output
-
Protection Circuit
- Reverse connection protection of the power supply
- Power surge protection
- Output overcurrent protection
- Reverse connection protection of the output
- Output surge protection
Environmental Resistance
Degree of Protection
IP65/IP67 (IEC60529)
Ambient Light
Incandescent lamp/Sunlight: 10,000 lux or less
Ambient Temperature
-20 to +55 °C (-4 to 131 °F) (No freezing)
Relative Humidity
35 to 85% HR (No condensation)
Vibration Resistance
- 10 to 55 Hz, Double Amplitude 1.5 mm (0.06"),
- 2 hours in each of the X, Y, and Z directions
Shock Resistance
1,000 m/s2*2, 6 times in each of the X, Y, and Z directions
Material
- Housing: Zinc die-cast (nickel plated)
- Indicator and Button Cover: PES
- Lens and Screen Cover: PMMA (scratch-resistant coating specifications)
- Cable Bush: PBT
Accessories
Instruction Manual, Laser Warning and Explanatory Labels
Weight
Approx. 125 g (including cable)*1
*1 The visible distance range is from 50 to 2200 mm. *2 The FDA (CDRH) laser classification is based on IEC60825-1, in accordance with the requirements of Laser Notice No.50. *3 145 mA or less (with load) *4 You can select the I/O from the following combinations. Control Output × 2, Control Output + External Input Control Output + Analog Output (only LR-TB5000/TB5000C/TB5000CL) External Input + Analog Output (only LR-TB5000/TB5000C/TB5000CL) (For more details on the configuration method, refer to the instruction manual). *5 Compatible with IO-Link v.1.1/COM2 (38.4 kbps) specification. You can download an installation file from the KEYENCE website (http://www.keyence.com). If you use the product in a location where files cannot be downloaded via the internet, please contact your nearest KEYENCE office.