Dedicated communication unit, RS-422A/485 type

Dedicated communication unit, RS-422A/485 type

Model N-R4

This document outlines the specifications for the Model N-R4.

Interface

RS-422A/485

Power Supply of Code Reader

5 VCD ±5% (650 mA)

Terminal Block

Input

  • Number of inputs: 2 inputs (IN1 and IN2)
  • Type of input: Bidirectional voltage input
  • Maximum nominal value: 26.4 VCD
  • Minimum voltage in ON: 15 VCD
  • Maximum current in OFF: 1 mA

Output

  • Number of outputs: 4 outputs (OUT1 to 4)
  • Type of output: Photo MOS relay output
  • Nominal load: 30 VCD, 100 mA
  • Leakage current in OFF: OFF: 0.1 mA or less
  • Residual voltage in ON: 1 V or less

Communication Specifications

  • Head port number: 1 (12-pin round connector)
  • Supported communication standards: Compliant with RS-232C
  • Communication speed: 4,800, 9,600, 19,200, 31,250, 38,400, 57,600, 115,200 bps
  • Number of data bits: 7/8 bits
  • Number of stop bits: 1/2 bits
  • Parity control: None/Even/Odd
  • Communication standard: Solid-state: NPN open-collector 100 mA max. (40 V max.)

Connector

1 (removable 5-pole connector)

Output Interface

Total extension length: 1.2 km (0.75 miles) or less

Nominal Value

  • Power supply voltage: 24 VCD +10%, -20%
  • Current consumption: 380 mA or less

Environmental Resistance

Operating Environment

  • No presence of dust or corrosive gases
  • Ambient temperature: 0 to +50 °C (32 to 122 °F) (No freezing)

Storage Temperature

-20 to +60 °C (-4 to 140 °F) (No freezing)

Relative Humidity

35 to 85% HR (No condensation)

Vibration Resistance

10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y and Z directions

Weight

Approx. 135 g (excluding connector)