Anemómetro PCE-AM 45
- Code / Model:
- Manufacturer: PCE Instruments
- Department: Test and measurement
- Category of products: Measurement of speed
- Sub-category: Machinery for the manufacture of electrical equipment
- You've seen it before.: 1
Anemometer with Beaufort Scale / Indication of wind direction /
Range: 0.3 ... 45.0 m/s / Memory for 960 values / Software /
Measurement of air speed and flow rate / Optional: ISO calibration certificate
Range: 0.3 ... 45.0 m/s / Memory for 960 values / Software /
Measurement of air speed and flow rate / Optional: ISO calibration certificate
The anemometer determines the air velocity through a winged wheel with a diameter of 65 mm. The anemometer accurately and reliably measures the air velocity in a range of 0.3 to 45 m/s. In addition to measuring the speed, the anemometer also determines the
Depending on the orientation of the wing wheel, the anemometer can also determine the direction of the wind. This is made possible by the gyroscope integrated into the anemometer sensor. Simultaneously the ambient temperature is also indicated in a range of 0 to 45 oC on the anem
The internal memory of the anemometer allows you to store up to 960 values. Through the micro USB interface you can transfer the values to a computer. The software can download it from our page (download section). With it you can analyze and edit the values measured with the anemometer. The software also
Depending on the orientation of the wing wheel, the anemometer can also determine the direction of the wind. This is made possible by the gyroscope integrated into the anemometer sensor. Simultaneously the ambient temperature is also indicated in a range of 0 to 45 oC on the anem
The internal memory of the anemometer allows you to store up to 960 values. Through the micro USB interface you can transfer the values to a computer. The software can download it from our page (download section). With it you can analyze and edit the values measured with the anemometer. The software also
- Battery power for mobile use
- Telescopic probe with a length of 270 mm or 540 mm
- 65 mm wing wheel aperture
- Measurement of air velocity and flow
- Range: 0,3 ... 45,0 m/s
- LCD screen backlit
- Telescopic probe with a length of 270 mm or 540 mm
- 65 mm wing wheel aperture
- Measurement of air velocity and flow
- Range: 0,3 ... 45,0 m/s
- LCD screen backlit
| Air speed | m/s | |
| Rate | 0,3 ... 45,0 m/s | |
| Resolution adopted by the Council | The following conditions shall apply: | |
| Accuracy | ±3 % ±0,1 m/s of the measurement value | |
| Air speed | The following information shall be provided: | |
| Rate | 60 ... 8800 ft/min | |
| Resolution adopted by the Council | The following is the list of the following: | |
| Accuracy | ±3 % ±20 ft/min of the measurement value | |
| Air speed | Other articles of heading 810 | |
| Rate | 0,6 ... 88,0 knots | |
| Resolution adopted by the Council | 0,01 knots | |
| Accuracy | ±3 % ±0,2 knots of the measuring value | |
| Air speed | The following conditions shall apply: | |
| Rate | The following conditions shall apply: | |
| Resolution adopted by the Council | The following conditions shall apply: | |
| Accuracy | ±3 % ±0,4 km/h of the measurement value | |
| Air speed | mph | |
| Rate | 0,7 ... 100 mph | |
| Resolution adopted by the Council | Other vehicles | |
| Accuracy | ±3 % ±0,2 mph of the measurement value | |
| Wind direction | ||
| Rate | 0 ... 360 degrees | |
| Resolution adopted by the Council | 1 ° | |
| Flow | The following information shall be provided: | |
| Rate | 0 ... 999900 m3/min | |
| Resolution adopted by the Council | The following is the list of the following: | |
| Surface adjustment | 0,001 ... 999 m2 | |
| The following information is provided for in the Annex to Implementing Regulation (EU) No 575/2013: | ||
| Rate | 0 ... 999900 ft3/min | |
| Resolution adopted by the Council | The following is the list of the following: | |
| Surface adjustment | 0,001 ... 999 m2 | |
| The temperature | °C | |
| Rate | 0 ... 45 °C | |
| Resolution adopted by the Council | The following conditions shall apply: | |
| Accuracy | ±1,0 °C | |
| °F | ||
| Rate | 32 ... 113 °F | |
| Resolution adopted by the Council | Other, of a kind used for the manufacture of goods | |
| Accuracy | The following conditions shall apply: | |
| Relative humidity | ||
| Rate | 10 ... 90 percent H.R. | |
| Resolution adopted by the Council | 0,1% H.r. | |
| Accuracy | ± 5% H.r. | |
| Other specifications | ||
| Sensor length | 270 ... 540 mm | |
| Sensor aperture | Ø65 mm | |
| Interface | Other electrical equipment | |
| Memory | 960 value | |
| Screen | LCD | |
| Food | 4 x 1.5 V batteries, of type AAA | |
| Absorbed power | 15 ... 20 mA 20 ... 25 mA 0 ... 8 μA | without backlighting with retro-lighting Standby |
| Low battery indication | Other, of a kind used for the manufacture of goods | |
| Operating conditions | 0 ... 50 °C / 40 ... 80 % H.r. without condensation | |
| Storage conditions | -20 ... 60 °C / < 80 % H.r. without condensation | |
| Dimension | 70 x 194 x 35 mm | |
| Weight | 400 g | |