Analizador de agua PCE-CP 22
- Code / Model:
- Manufacturer: PCE Instruments
- Department: Test and measurement
- Category of products: Measurement of water
- Sub-category: - What ?
- You've seen it before.: 1
Multi-parameter water analyzer with Bluetooth interface / Software / Cloud service /
Synchronization of values throughout the system / Selection of 9 different measurement parameters /
For the measurement of, for example, ammonia, copper, phosphate, iron, nitrate, nitrite, pH, potassium and urea
Synchronization of values throughout the system / Selection of 9 different measurement parameters /
For the measurement of, for example, ammonia, copper, phosphate, iron, nitrate, nitrite, pH, potassium and urea
The multiparametric water analyzer is a device that stands out among water analyzers. With this multiparametric water analyzer it can determine many measurement parameters. Thanks to this, it can use this multiparametric water analyzer for different types of tasks. To perform a
The multi-parameter water analyzer automatically stores the value of each measurement. The multi-parameter water analyzer integrates a memory for a total of 256 values. It can transfer stored values from the multi-parameter water analyzer, since it integrates a
The multi-parameter water analyzer automatically stores the value of each measurement. The multi-parameter water analyzer integrates a memory for a total of 256 values. It can transfer stored values from the multi-parameter water analyzer, since it integrates a
- Up to 9 parameters to be selected
- Adjustment of units: mg/l, ppm
- Bluetooth connection with App
- Interchangeable and lockable cup
- LEDs of 503 nm / 570 nm / 620 nm
- Automatically disconnected
- Menu available in different languages
- Light detector: photodiode
- Cable size: 36 x ø 21 mm (10 ml)
- Adjustment of units: mg/l, ppm
- Bluetooth connection with App
- Interchangeable and lockable cup
- LEDs of 503 nm / 570 nm / 620 nm
- Automatically disconnected
- Menu available in different languages
- Light detector: photodiode
- Cable size: 36 x ø 21 mm (10 ml)
| Other, of a thickness of not more than 10 mm | |
| Measurement range | 0,00 ... 0,12 mg/l |
| 0,12 ... 0,25 mg/l | |
|
| 0,25 ... 0,57 mg/l |
| 0,57 ... 1,21 mg/l | |
| Accuracy | 0,02 mg/l |
| 0,04 mg/l | |
| 0,06 mg/l | |
| 0,09 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| Copper | |
| Measurement range | 0,00 ... 2,00 mg/l |
| 2,00 ... 3,00 mg/l | |
| 3,00 ... 5,00 mg/l | |
| Accuracy | 0,20 mg/l |
| 0,31 mg/l | |
| 0,44 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| Other |
|
| Measurement range | 0,00 ... 0,40 mg/l |
| 0,40 ... 1,20 mg/l | |
| 1,20 ... 2,00 mg/l | |
| Accuracy | 0,04 mg/ |
| 0,12 mg/l | |
| 0,20 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| Iron | |
| Measurement range | 0,00 ... 0,20 mg/l |
| 0,20 ... 0,60 mg/l | |
| 0,60 ... 1,00 mg/l | |
| Accuracy | 0,02 mg/l |
| 0,04 mg/l | |
| 0,08 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| Other, of a kind used for the manufacture of goods | |
| Measurement range | 0 ... 20 mg/l |
| 20 ... 40 mg/l | |
| 40 ... 60 mg/l | |
| 60 ... 100 mg/l | |
| Accuracy | 2 mg/l |
| 4 mg/l | |
|
| 6 mg/l |
| 10 mg/l | |
| Resolution adopted by the Council | 1 mg/l |
| Other, of a kind used for the manufacture of goods | |
| Measurement range | 0,00 ... 0,25 mg/l |
| 0,25 ... 0,40 mg/l | |
| 0,40 ... 1,30 mg/l | |
| 1,30 ... 1,64 mg/l | |
| Accuracy | 0,02 mg/l |
| 0,06 mg/l | |
| 0,09 mg/l | |
| 0,12 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| pH | |
| Measurement range | 6,50 ... 8,40 pH |
| Accuracy | 0,11 pH |
| Resolution adopted by the Council | 0,01 pH |
| Potassium | |
| Measurement range | 0,8 ... 3,0 mg/l |
| 3,0 ... 7,0 mg/l | |
| 7,0 ... 10,0 mg/l | |
| 10,0 ... 12,0 mg/l | |
| Accuracy | 0,3 mg/l |
| 0,4 mg/l | |
| 0,5% or more | |
| 1 mg/l | |
| Resolution adopted by the Council | 0,1 mg/l |
| Other | |
| Measurement range | 0,00 ... 0,30 mg/l |
| 0,30 ... 0,60 mg/l | |
| 0,60 ... 1,00 mg/l | |
| 1,00 ... 1,50 mg/l | |
| 1,50 ... 2,50 mg/l | |
| Accuracy | 0,05 mg/l |
| 0,06 mg/l | |
| 0,09 mg/l | |
| 0,12 mg/l | |
| 0,19 mg/l | |
| Resolution adopted by the Council | 0,01 mg/l |
| Other specifications | |
| Hardness units | The following conditions shall apply: |
| °dH (German hardness), °e | |
| (English hardness degree/Clark degree) | |
| °f (French degree of hardness) | |
| Calibration | The following shall be added: |
| Light source | The following is the list of the components of the LED |
| Other light detectors | Other |
| Food | 4 x 1.5V batteries, type AA |
| Dimensions of the bucket | 36 x ø 21 mm (10 ml) |
| Languages of the menu | German, French, Spanish, English, Italian |
| Memory | Automatic recording and reading of securities |
| Memory capacity | 256 values |
| Interface | Bluetooth connection with App and software |
| Automatically disconnected | After 300 seconds of inactivity |
| Operating conditions | 5 ... 45 °C, 20 ... 90 % H.r., not condensed |
| Storage conditions | 5 ... 45 °C, 20 ... 90 % H.r., not condensed |
| Dimension | Other, of a width of not more than 600 mm |
| Weight | Other, of a kind used for the manufacture of goods |