Amperímetro PCE-LT 12

Amperímetro PCE-LT 12

Multifunctional amplifier / For electricians and network workers /
Network connection cable analysis / Telephone connection testing /
Voltage and current measurement / NCV / Retro-lit display
The amp is a multifunctional measuring instrument. In addition to measuring the standard voltage and current parameters, the amp has a network analysis. With this amp you can check for example LAN connections and their functionality. You can also check with this amp telephone connections. If you
Thanks to its cable detection function, the user can easily locate the desired cable with this amperometer. You simply need to connect the multimeter to the plug of a particular line. Now the amperometer acts as a transmitter. With the receiver included in the transmission you can easily detect the
To check whether a given line has voltage, the amperometer has the NCV (Not Connected Voltage) function. You simply have to place the multimeter over the line. The multimeter signals the user acoustically and visually that the line has voltage. Thanks to this function

- Extensive network connection testing
- Check for telephone connections
- Acoustic cable detection function
- Robust housing for mobile use
- Measurement of voltage, current and resistance
- Contactless voltage sensing (NCV)


   
Parameters  
Alternating voltage  
Rate Resolution adopted by the Council Accuracy
Other electricity 0,1 mV ±(0,8% + 5 digits)
2 V 1 mV ±(0,8% + 5 digits)
20 V 0,01 V ±(0,8% + 5 digits)
Other vehicles 0,1 V ±(0,8% + 5 digits)
Other vehicles 1 V
±(0,8% + 5 digits)
     
The maximum input voltage shall be 750 VAC.
Frequency range: 40 ... 400 Hz
RMS conversion
     
Continuous voltage  
Rate Resolution adopted by the Council Accuracy
Other electricity 0,1 mV ±(0,5% + 5 digits)
2 V 1 mV ±(0,5% + 5 digits)
20 V 0,01 V ±(0,5% + 5 digits)
Other vehicles 0,1 V ±(0,5% + 5 digits)
Other electrical equipment 1 V ±(0,8% + 5 digits)
     
The maximum input voltage shall be 1000 VDC.
 
Other power  
Rate Resolution adopted by the Council Accuracy
Other, of a kind used for the manufacture of goods 0,1 μA ±(1,5% + 5 digits)
Other, not further worked than hot-rolled 1 μA ±(1,5% + 5 digits)
20 mA 0,01 mA ±(1,5% + 5 digits)
200 mA 0,1 mA ±(1,5% + 5 digits)
2 A 0,001 A ±(3,0 % + 5 digits)
20 A 0,01 A ±(3,0 % + 5 digits)
     
Protection against overload in μA, mA: 200 mA/1000 V Fused fuse
Protection against overload in A: 10 A / 500 V Fused fuse
The maximum input current μA: 2000 μA
The maximum input current mA: 200 mA
Maximum input current A: 10 A
Frequency range: 40 ... 400 Hz
RMS conversion
 
Continuous current  
Rate Resolution adopted by the Council Accuracy
Other, of a kind used for the manufacture of goods 0,1 μA ±(1,2% + 5 digits)
Other, not further worked than hot-rolled 1 μA ±(1,2% + 5 digits)
20 mA 0,01 mA ±(1,2% + 5 digits)
200 mA 0,1 mA ±(1,2% + 5 digits)
2 A 0,001 A ±(2,0 % + 5 digits)
20 A 0,01 A ±(2,0 % + 5 digits)
     
Protection against overload in μA, mA: 200 mA/1000 V Fused fuse
Protection against overload in A: 10 A / 500 V Fused fuse
The maximum input current μA: 2000 μA
The maximum input current mA: 200 mA
Maximum input current A: 10 A
 
The resistance  
Rate Resolution adopted by the Council Accuracy
200 Ω 0,1 Ω ±(1,0 % + 5 digits)
2 kΩ 0,001 kΩ ±(1,0 % + 5 digits)
20 kΩ 0,01 kΩ ±(1,0 % + 5 digits)
Other, of a kind used for the manufacture of goods 0,1 kΩ ±(1,0 % + 5 digits)
2 MΩ 0,001 MΩ ±(1,0 % + 5 digits)
20 MΩ 0,01 MΩ ±(1,0 % + 5 digits)
     
Testing of diodes    
Rate Resolution adopted by the Council Accuracy
Indicates the live voltage 1 mV - What ?
     
Continuity test    
Rate Resolution adopted by the Council Accuracy
The sound signal shall be: 0,1 Ω - What ?
     
Other specifications  
Selection of range Automatic and manual
Measurement with receiver Detection of cable breakage
Cable conduction detection
Measurement of network function Detection of open and closed circuits, faulty connections, split torque, reverse connection, network integration check, armour check
Other functions The following information is provided by the Commission:
Screen The Commission has also adopted a number of measures to combat fraud.
Over-ranking indication 'OL'
Automatically disconnected After 15 minutes of inactivity
Fuses The following conditions shall apply:
Indication of battery status Indication when the battery is low
Food 9 V battery
Operating temperature 0 ... 40 °C
Storage temperature -10 ... 50 °C
Dimension Other materials of heading 83.0
Weight Approximately 400 g (including stack)
 