Amperímetro PCE-CM 3

Amperímetro PCE-CM 3

Open jaw diameter up to 200 A AC / AC/DC voltage measurement / Simple current measurement / LCD screen / Continuity test / Thermometer
The open jaw amp is especially suitable for measuring alternating currents in distribution cabinets and any circuit that should not be interrupted. The range of current measurement ranges from 0 to 200 A. In addition to current measurement, you can also measure with this open jaw amp up to
The compact dimensions and light weight, as well as its robust housing, are characteristics of this open jaw ampere.

- Amperature up to 200 A
- Compact sizes
- A sturdy plastic case
- Multi-meter function
- Powered by batteries
- LCD screen backlit

Continuous voltageRateResolution adopted by the CouncilAccuracy
 4 V DC1 mV±(1,2% of the value + 2 d)
Other electrical equipment10 mV±(1,5% of the value + 2 d)
Other electrical equipmentOther electrical equipment±(1,5% of the value + 2 d)
Other electrical equipment1 V±(2 % of the value + 2 d)
Impedance of entry10 MΩ
Protection against overpressureOther electrical equipment
Other electrical equipment
 
Alternating voltageRateResolution adopted by the CouncilAccuracy
 4 V AC1 mV±(1,5% of the value + 5 d)
40 V AC10 mV±(1,5% of the value + 2 d)
Other electrical equipmentOther electrical equipment±(1,5% of the value + 2 d)
Other, of a kind used for the manufacture of goods1 V±(2 % of the value + 2 d)
Impedance of entry10 MΩ
Protection against overpressureOther electrical equipment
Other electrical equipment
Frequency range50 ... 400 Hz
 
Other powerRateResolution adopted by the CouncilAccuracy
 200 A AC100 mA±(3,0% of the value + 5 d)
Protection is overloaded200 A AC
Frequency range50 ... 60 Hz
 
The resistanceRateResolution adopted by the CouncilAccuracy
 400 Ω0,1 Ω±(1 % of the value + 4 d)
4 kΩ1 Ω±(1,5% of the value + 4 d)
Other, of a kind used for the manufacture of goods10 Ω±(1,5% of the value + 4 d)
Other, of a kind used for the manufacture of goods100 Ω±(1,5% of the value + 4 d)
4 MΩ1 kΩ±(2,5% of the value + 4 d)
40 MΩ10 kΩ±(3,5% of the value + 4 d)
Protection against overpressureOther electrical equipment
The following information is provided:
 
FrequencyRateResolution adopted by the CouncilAccuracy
 40 Hz0,01 Hz±(1 % of the value + 2 d)
400 Hz0,1 Hz±(1,2% of the value + 2 d)
4 KHz1 Hz±(1,2% of the value + 2 d)
Other power units10 Hz±(1,2% of the value + 2 d)
400 KHz100 Hz±(1,2% of the value + 2 d)
10 MHz1 KHz±(1,2% of the value + 2 d)
Sensitivity to input10 mV RMS
Protection against overpressureOther electrical equipment
The following information shall be provided:
 
Working cycleRateResolution adopted by the CouncilAccuracy
 0,1% to 99,9%0,1%±1,2% of the value of ± 2 d
Sensitivity to input1 V RMS
The width of impulsesOther, of a kind used for the manufacture of goods
Protection against overpressureOther electrical equipment
The following information shall be provided:
 
The temperatureRateResolution adopted by the CouncilAccuracy
 -20 ... 760 °CThe following conditions shall apply:
1 °C
±(3 % of the value + 5 °C)
4 ... 1400 °F0,1 °F
1 °F
±(3 % of the value + 8 °F)
Protection against overpressureOther electrical equipment
The following information is provided:
Heat connectionType-K connecting adapter
 
CapacityRateResolution adopted by the CouncilAccuracy
 4 nF0,1 nF±(5% of the value + 20 d)
40 nF1 nF±(3 % of the value + 5 d)
Other, not further worked than hot-rolled 10 nF±(3 % of the value + 5 d)
4 μFOther±(3 % of the value + 5 d)
Other, of a kind used for the manufacture of goods1 μF±(3 % of the value + 5 d)
Other, of a thickness of not more than 10 mm10 μF±(3 % of the value + 10 d)
Protection against overpressureOther electrical equipment
The following information is provided:
 
The verification functionTest conditionsIndication of the type
Test of diodesThe test current:
0,5% or more
Reverse voltage: 1,5 V
Direct voltage of the diode
Continuity testThe voltage of the open circuit: 0,5 VNoise when the resistance < 50 Ω
Protection against overpressureOther electrical equipment
The following information is provided:
 
General technical specifications
The pressure of the gasket shall be measured.Approximately 17 mm
ScreenOther, of a kind used for the manufacture of goods or services
Continuity testNoise when the resistance is less than 50 Ω
Test currentApproximately 0,5 mA
Voltage in open circuitOther, of a kind used for the manufacture of goods
Battery status indicationOn-screen symbol when the voltage is low
Indication of overrankingYes, the screen says "OL"
The amount of the security shall be reported in the following table:3 Hz
Other heat pumpsOther, of a kind used for the manufacture of goods
Impedance of entry10 MΩ
Operating conditions5 ... 40 °C / 80 % H.r., not condensed
Storage conditions-20 ... +60 °C / 80 % H.r., not condensed
Maximum operating altitudeOther, of a kind used for the manufacture of goods
Food2 x 1.5 V batteries, of type AAA
Automatically disconnected30 minutes
SecurityThe following information shall be provided:
The following conditions shall apply:
Other vehicles
Degree of pollution2