55mm Head

55mm Head

Model

IX-055

Reference Distance

55 mm / 2.17"

Measurement Distance

45 to 65 mm / 1.77" to 2.56"

Detection Area

Scanning Mode

  • Measurement distance of 45 mm (1.77"): 27.5 × 20.5 mm (1.08" × 0.81") (min.)
  • Measurement distance of 55 mm (2.17"): 32.5 × 24.5 mm (1.28" × 0.96") (min.)
  • Measurement distance of 65 mm (2.56"): 37.5 × 28.5 mm (1.48" × 1.12") (Direction X) × (Direction Y)

Line Mode

  • Measurement distance of 45 mm (1.77"): 27.5 mm (1.08") (min.)
  • Measurement distance of 55 mm (2.17"): 32.5 mm (1.28") (min.)
  • Measurement distance of 65 mm (2.56"): 37.5 mm (1.48") (Direction X)

Laser Light Source

Semiconductor red laser with a wavelength of 660 nm (visible light)

Laser Class

Class II Laser Product (FDA [CDRH] Part 1040.10), Class 2 Laser Product (IEC 60825-1: 2014)

Output

0.95 mW (FDA (CDRH) Part 1040.10), 1.6 mW (IEC 60825-1: 2014)

Minimum Detectable Object Size

Scanning Mode

ø0.7 mm / ø0.03" *2

Line Mode

0.7 mm × 0.7 mm / 0.03" × 0.03" *2

Repeatability

10 µm *3

Estimated Detection

(Estimated detection: When measuring the height between two points, the minimum step difference is as follows.
IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3

Sampling Cycle

Scanning Mode

120 ms (min.) (typical)

Line Mode

6 ms / 11 ms (selectable)

Image Receiver Element

Monochromatic CMOS image sensor

Image Capture Illumination

Light Source

Red LED

Illumination Method

Pulsed illumination

Temperature Characteristics

0.04% of F.E./°C *4

Environmental Resistance

Degree of Protection

IP67

Ambient Light

Incandescent lamp, 5000 lux or less *5

Ambient Temperature

0 to +45°C / 32 to 113°F (without freezing) *6

Relative Humidity

35 to 85% RH (no condensation)

Vibration Resistance

10 to 55 Hz; double amplitude 1.5 mm (0.06"); 2 hours in each of the X, Y, and Z directions

Shock Resistance

500 m/s² *2, 3 times in each of the 3 directions

Material

Main unit housing: zinc die-casting / Front cover: glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector: zinc die-casting

Weight

Approx. 190 g

*Notes:*
  • *1 X: direction of the long side of the laser, Y: direction of the short side of the laser
  • *2 With a correctly mounted reference distance. When measured with the height tool, minimum measurement point and without position adjustment, in scanning mode. When measured with the height tool, minimum tool window size and without position adjustment, in line mode.
  • *3 Measured at the center of the field of view in scanning mode, using the “max.” measurement point of a KEYENCE reference object (white diffuser) at the reference distance.
  • *4 At the reference distance of the object. The F.E. (scale backgrounds) for each model are as follows: IX-055: ±10 mm (0.39"), IX-080: ±18 mm (0.71"), IX-150: ±50 mm (1.97"), IX-360: ±80 mm (3.15")
  • *5 Using the default setting with a laser light source as the target.
  • *6 With metal mounting.

Products Related