Amperímetro PCE-PCM 3

Amperímetro PCE-PCM 3

The following information is provided by the manufacturer:
The following conditions shall apply:
With this clamp ampere, it can measure alternating currents up to 1000 A AC without any problems. Simultaneously, it can measure voltages up to 1000 V AC/DC. The ampere also measures the active, reactive and apparent power up to 750 kW. Another function of
With the NCV (Not Connected Voltage) function, you can check with the ampmeter if a line or cable is under voltage without the need to perform a contact measurement. This makes the user's work quite easy. In addition to all functions, you can connect the ampmeter to

- Active, reactive and apparent power
- Measurement up to 20th harmonic waveform
- Contactless measuring device (NCV)
- Measurement of the start intensity
- Measurement of current up to 1000 A AC
- Bluetooth interface is


Environmental conditions: 23 °C ±5 °C, < 75% H.r.
The following is the list of the parameters: Rate Resolution adopted by the Council Accuracy
AC current 60 A 0,01 A ± 2 % + 8 digits
600 A 0,1 A ± 2 % + 8 digits
1000 A 1 A ± 2 % + 8 digits
The maximum input current is 1000 A AC
Frequency range 40 ... 400 Hz
AC starting current 60 A 0,01 A For reference only
600 A 0,1 A ± 5% + 60 digits
1000 A 1 A ± 5% + 60 digits
Full time: 100 ms
Range: 20 ... 1000 A
Frequency range: 40 .... 400 Hz
DC voltage 6 V 0,001 V ± 0,5% + 5 digits
60 V 0,01 V ± 0,5% + 5 digits
Other electrical equipment 0,1 V ± 0,5% + 5 digits
Other electrical equipment 1 V ± 0,8% + 4 digits
The input impedance shall be:
Maximum input voltage: 750 V AC (actual value) or 1000 V DC
Air conditioning 6 V 0,001 V ± 0,6% + 4 digits
60 V 0,01 V ± 0,6% + 4 digits
Other electrical equipment 0,1 V ± 0,6% + 4 digits
Other electrical equipment 1 V ± 0,8% + 4 digits
The input impedance shall be:
Maximum input voltage: 750 V AC (actual value) or 1000 V DC
Frequency range: 40 ... 400 Hz
Frequency measurement with the current measurement function The frequency of the sound 0,01 Hz ±1,5% + 5 digits
The frequency of the sound is: 0,1 Hz ±1,5% + 5 digits
Range: 10 ... 1 kHz
The input signal range: > 20 AC (actual value)
The input current increases with the measurement frequency.
The maximum input current: 1000 A AC (actual value)
Frequency measurement with the voltage measurement function The frequency of the sound 0,01 Hz ±1,5% + 5 digits
The frequency of the sound is: 0,1 Hz ±1,5% + 5 digits
Other power supplies Other, of a kind used for the manufacture of goods ±1,5% + 5 digits
Range: 10 ... 10 kHz
The input signal range: > 1 VAC (effective value)
The input current increases with the measurement frequency.
The maximum input voltage shall be 1000 VAC (actual value)
Frequency measurement The frequency of the signal shall be: 0,001 Hz ± 0,3% + 5 digits
The frequency of the sound 0,01 Hz ± 0,3% + 5 digits
Other power supplies 0,1 Hz ± 0,3% + 5 digits
The frequency of the sound is: Other, of a kind used for the manufacture of goods ± 0,3% + 5 digits
Other power generators Other, of a kind used for the manufacture of goods ± 0,3% + 5 digits
Other power units Other, not further worked than hot-rolled ± 0,3% + 5 digits
The frequency of the transmission shall be: 0,001 MHz ± 0,3% + 5 digits
Protection against overvoltage: 1000 V DC or 750 V AC (effective value)
Input voltage range > 2V (when the input voltage increases the frequency also increases)
Working cycle
(Duty cycle)
0,1% to 99,9% 0,1% ± 0,3% + 5 digits
Frequency range: 10 ... 10 kHz
The following shall be reported:
(The tension increases with frequency)
Working cycle with the current measurement function Frequency range: 10 ... 1 kHz
The amount of the difference between the two amounts shall be calculated on the basis of the following data:
Working cycle with the voltage measurement function Frequency range: 10 ... 1 kHz
The value of the input current shall be the sum of the values of the input current.
The input impedance shall be: 1MΩ
The resistance 600 Ω 0,1 Ω ± 0,8% + 3 digits
6 kΩ 0,001 kΩ ± 0,8% + 3 digits
Other, of a kind used for the manufacture of goods 0,01 kΩ ± 0,8% + 3 digits
Other, of a kind used for the manufacture of goods 0,1 kΩ ± 0,8% + 3 digits
6 MΩ 0,001 MΩ ± 2 % + 5 digits
60 MΩ 0,1 MΩ ± 2 % + 5 digits
Measurement of voltage: approximately 0,78 V
Protection against overvoltage: 750 V DC, 1000 V AC (effective value)
Continuity test 600 Ω 0,1 Ω - What ?
The sound signal shall be:
Test voltage: 1,48 V
Protection against overvoltage: 750 V DC, 1000 V AC (effective value)
Capacity Other non-revenue Other, not further worked than hot-rolled ±3 % + 5 digits
Other, not further worked than hot-rolled 0,01 nF ±3 % + 5 digits
Other, not less than €1 0,1 nF ±3 % + 5 digits
Other, not further worked than hot-rolled 0,001 μF ±3 % + 5 digits
Other, of a thickness of not more than 0,15 mm 0,01 μF ±3 % + 5 digits
Other, of a thickness of not more than 0,9 mm 0,1 μF ±3 % + 5 digits
The following table shows the following: 0,001 mF ±3 % + 5 digits
Other, not further worked than hot-rolled 0,01 mF ±3 % + 5 digits
Protection against overvoltage: 750 V DC, 1000 V AC (effective value)
Measurement of diodes 3 V 0,001 V - What ?
Anodic DC: approximately 1 mA
The following shall be added to the list of the following:
Protection against overvoltage: 750 V DC, 1000 V AC (effective value)
The measurement of single-phase power 3 W / VA / Var 0,01 W / VA / Var ±3 % + 5 digits
100 W / VA / Var The following conditions shall apply: ±3 % + 5 digits
Other electricity 1 W / VA / Var ±3 % + 5 digits
10 kW / VA / Var The following conditions shall apply: ±3 % + 5 digits
The following conditions shall apply: The following conditions shall apply: ±3 % + 5 digits
The following conditions shall apply: 1 kW / VA / Var ±3 % + 5 digits
Smaller measuring current: 1 mA
The measuring voltage shall be less than 1 V.
Power factor
Capacitive / inductive
0,1 ... 1 0,001 ± 5% + 5 digits
Smaller measuring current: 1 mA
The measuring voltage shall be less than 1 V.
Other, of a kind used for the manufacture of goods 1 - What ? ±3 % + 10 digits
  Two ... six - What ? ±3,5% + 10 digits
  7 ... 8 - What ? ±4,5% + 10 digits
  9 ... 10 - What ? ± 5% + 10 digits
  11 ... 15 - What ? ±7 % + 10 digits
  16 ... 20 - What ? ± 10% + 10 digits
Smaller measuring current: 1 mA
The measuring voltage shall be less than 1 V.
The resolution depends on the range of measurement of the voltage
 
Generic specifications
Rate Automatic or manual, adjustable
The maximum voltage range 1000 V DC or 750 V AC
Height above sea level Maximum 2000 m
Screen LCD
Maximum displayed display 5999 digits
Upper overrange 'OL'
Lower overrange -O.L.
Measurement quota 3 Hz
Automatically disconnected After 30 minutes
Food 9 V battery
Indication of the state of the battery Symbol when the voltage is too low
The temperature coefficient 0,1 x accuracy x °C*
Operating conditions 0 ... 40 °C, 32 ... 104 °F
Storage conditions -10 ... 60 °C, 14 ... 140 °F
Dimension 238 x 92 x 50 mm
Weight Approximately 420 g (with batteries)
The indicated precision is applicable under environmental conditions of 18 ... 28 °C, 65 ... 83 °F.

*The temperature is calculated on the basis of the difference in temperature between the operating conditions and the current ambient temperature.
Example:
The current temperature is above the operating temperature:
The following conditions shall apply:
The current temperature is below the operating temperature:
The following conditions shall apply: