SOLICITAR PRECIOSClassifications
-
Object Classification Code:
Q
-
ETIM 4:
EC000066 - Magnet contactor, AC-switching
-
ETIM 5:
EC000066 - Magnet contactor, AC-switching
-
ETIM 6:
EC000066 - Power contactor, AC switching
-
ETIM 7:
EC000066 - Power contactor, AC switching
-
UNSPSC:
39121529
Container Information
-
Package Level 1 Units:
1 piece
-
Package Level 1 Width:
78 mm
-
Package Level 1 Depth / Length:
76 mm
-
Package Level 1 Height:
47 mm
-
Package Level 1 Gross Weight:
0.34 kg
-
Package Level 1 EAN:
3471522032805
-
Package Level 2 Units:
box 63 piece
-
Package Level 2 Width:
300 mm
-
Package Level 2 Depth / Length:
245 mm
-
Package Level 2 Height:
308 mm
-
Package Level 2 Gross Weight:
21.42 kg
-
Package Level 3 Units:
1220 piece
Certificates and Declarations (Document Number)
-
BV Certificate:
BV_2634H07559E0
-
CB Certificate:
CB_CN44759
-
CCC Certificate:
CCC_2018010304059156
CCC_2004010309130463 -
CSA Certificate:
CSA_1041746
-
Declaration of Conformity - CE:
1SBD250802U1000
-
DNV Certificate:
DNV-GL_TAE00000TX
-
DNV GL Certificate:
DNV-GL_TAE00000TX
-
EAC Certificate:
EAC_RU C-FR ME77 B01010
-
Environmental Information:
1SBD250001E1004
-
GOST Certificate:
GOST_POCCFRME77B07175
-
Instructions and Manuals:
FPTC407721P0001
-
LR Certificate:
LRS_9830011E4
-
RINA Certificate:
RINA_ELE172319XG001
-
RMRS Certificate:
RMRS_0507015250
-
RoHS Information:
1SBD250802U1000
-
UL Certificate:
UL_20160205-E312527-10-2
-
UL Listing Card:
UL_E312527
Environmental
-
Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C -
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
-
Maximum Operating Altitude Permissible:
3000 m
-
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 20 K40
Shock Direction: B2 15 K40
Shock Direction: C1 20 K40
Shock Direction: C2 20 K40
Closed, Shock Direction: B1 10 K40
Open, Shock Direction: B1 5 K40 -
RoHS Status:
Following EU Directive 2011/65/EU
Technical
-
Number of Main Contacts NO:
4
-
Number of Main Contacts NC:
0
-
Number of Auxiliary Contacts NO:
0
-
Number of Auxiliary Contacts NC:
0
-
Standards:
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
-
Rated Operational Voltage:
Main Circuit 690 V
-
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A
-
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 25 A
(690 V) 55 °C 22 A
(690 V) 70 °C 18 A -
Rated Operational Current AC-3 (Ie):
(220 / 230 / 240 V) 55 °C 9 A
(380 / 400 V) 55 °C 9 A
(415 V) 55 °C 9 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A -
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 2.2 kW
(380 / 400 V) 2.5 kW
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW -
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
-
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
-
Short-Circuit Protective Devices:
gG Type Fuses 25 A
-
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A -
Maximum Electrical Switching Frequency:
AC-1 600 cycles per hour
AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour -
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V -
Rated Impulse Withstand Voltage (Uimp):
8 kV
-
Mechanical Durability:
10 million
-
Maximum Mechanical Switching Frequency:
3600 cycles per hour
-
Rated Control Circuit Voltage (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V -
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 8 2 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 8 2 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 80 V·A
Average Holding Value 50 / 60 Hz 8 2 V·A
Average Pull-in Value 50 Hz 74 V·A
Average Pull-in Value 60 Hz 70 V·A -
Operate Time:
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms -
Connecting Capacity Main Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm² -
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm² -
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
-
Connecting Terminals (delivered in open position) Main Poles:
M 3.5 (+,-) pozidriv 2 screw with cable clamp
-
Terminal Type:
Screw Terminals
Dimensions
-
Product Net Width:
44 mm
-
Product Net Depth / Length:
74 mm
-
Product Net Height:
74 mm
-
Product Net Weight:
0.34 kg
Popular Downloads
-
Data Sheet, Technical Information:
1SBC100122C0202_Ch02
-
Instructions and Manuals:
FPTC407721P0001
Ordering
-
Minimum Order Quantity:
1 piece
-
Customs Tariff Number:
85364900
Productos similares
-
MOSTRAR
DETALLES
Siemens 3RT1944-6A contactos de repuesto para contactor
-
MOSTRAR
DETALLES
Contactor LC1D18M7 Fabricante: SCHNEIDER ELECTRIC Modelo: LC1-D18-M7
-
MOSTRAR
DETALLES
100C09KJ10 Contactor 9A 1NA 24VAC 4KW 50/60HZ
-
MOSTRAR
DETALLES
Schneider A9C20732
-
MOSTRAR
DETALLES
Schneider A9C20834
-
MOSTRAR
DETALLES
LC1DT32BL Contactor Tesys D - 4P