Fiber Amplifier FS-V31CP Keyence
- Code / Model:
- Manufacturer: Keyence
- Department: Automation and control of processes
- Category of products: Industrial sensors
- Sub-category: Fiber optic sensors
- You've seen it before.: 11
Model
FS-V31CP
Type
1 output + 1 input with M8 connector
Emission
PNP
Main Unit/Expansion Unit
Unit
Signal Output
- 1 output
- Monitor output (1 to 5 V)
- N/A
External Input
- 1 input
- M8 connector
Light Source
4-element red LED (wavelength: 640 nm)
Response Time
33 s (HIGH SPEED)/250 s (FINE)/500 μs (TURBO)/1 ms (SUPER TURBO)/4 ms (ULTRA TURBO)/16 ms (MEGA TURBO)
Output Selection
Activated by light (LIGHT-ON)/activated by darkness (DARK-ON) (Selection by selector)
Display Indicator
Operating indicator: Red LED/Dual digital monitor: Double 7-segment display, Set value (4-digit green LED indicator) and Target value (4-digit red LED indicator). Current value range: 0 to 64,512; Excess gain: 0P to 999P, Retention function: It is possible to view the peak and minimum retention values. Selectable between 5 variations
LED bar monitor: Excess gain displayed (85% to 115% in 7 steps), scale presentation
Detection Mode
Light intensity (area detection possible, automatic sensitivity-tracking function included)
Timer Function
- Activation delay timer/Deactivation delay timer/Single shot timer/Timer + Deactivation delay timer/Timer + Single shot timer
- Selectable timer duration: 0.1 to 9,999 ms, Maximum error relative to the set value: 10% max.
Signal Output
Open-collector PNP 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when expansion unit(s) is/are connected), Residual voltage: 1 V max.
External Input
Input time: 2 ms (ON)/20 ms (OFF) min.*2
Expansion Units
Up to 16 expansion units can be connected (a total of 17 units). Note that the type with 2 outputs should be counted as two units.
Number of Interference Prevention Units
Normal operation: HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台
Size
30.3 mm (height) x 9.8 mm (width) x 71.8 mm (depth) 1.19" (height) x 0.39" (width) x 2.83" (depth)
Classification
Power Supply Voltage
12 to 24 VCD (±10%), residual ripple ratio (P-P) 10% max. Class 2
Power Consumption
Normal: 750 mW max. (Using 24 V, 31 mA max., using 12 V, 40 mA max.)/Energy saving 580 mW max. (Using 24 V, 24 mA max., using 12 V, 28 mA max.)*3
Environmental Resistance
Ambient Illumination
Incandescent lamp: 20,000 lux max. Sunlight: 30,000 lux max.
Operating Ambient Temperature
From -10 to +55°C 14 to 131°F, no freezing*4
Operating Ambient Humidity
35 to 85% HR (no condensation)
Shock Resistance
500 m/s2 in the X, Y and Z directions, 3 times respectively
Vibration
10 to 55 Hz, Double amplitude: 1.5 mm 0.06", 2 hours each on the X, Y and Z axes
Structure Material
Polycarbonate
Accessories
N/A
Weight
Approx. 80 g