Logger de datos PCE-FWS 20N
- Code / Model:
- Manufacturer: PCE Instruments
- Department:
- Category of products:
- Sub-category: Instruments and equipment
- You've seen it before.: 1
Wireless data logger for measuring wind direction, wind speed, temperature, relative humidity and rainfall / Adjustable alarm function / USB interface / Analysis software / Solar module and transmitter power batteries / Broadcast frequency: 868 MHz
This wireless data logger is a multifunctional equipment that will meet your expectations. Both in the private and professional sphere, this unlambric data logger will fascinate you. This data logger allows you to accurately detect the direction of the wind, wind speed, temperature,
This data logger is equipped with the latest technology in weather analysis. The transmitter is powered by a solar module and rechargeable batteries. The touch screen allows you to easily retrieve data logger values. The USB port, which includes the USB cable, allows you to transmit data log
This data logger is equipped with the latest technology in weather analysis. The transmitter is powered by a solar module and rechargeable batteries. The touch screen allows you to easily retrieve data logger values. The USB port, which includes the USB cable, allows you to transmit data log
- Software for the analysis of recorded data
- 7 inch backlit touchscreen
- Weather forecasting function
- Automatic time band adjustment thanks to DCF
- Adjustable alarms when the measurement value is exceeded
- Wind direction and speed
- Temperature and humidity indication
- Powering the external module by a solar panel
- 7 inch backlit touchscreen
- Weather forecasting function
- Automatic time band adjustment thanks to DCF
- Adjustable alarms when the measurement value is exceeded
- Wind direction and speed
- Temperature and humidity indication
- Powering the external module by a solar panel
| Interior | ||
| Measurement function | ||
| Air temperature | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 0 ... +50 °C | 0,1 | - What ? |
| 32 .. 122 °F | ||
| Measurement function | ||
| Relative humidity | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 1 ... 99 percent | 1 % | - What ? |
| Measurement function | ||
| Air pressure | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 300 ... 1100 hPa | 0,1 hPa | ± 3 hPa |
| 8,85 ... 32,5 inHg | 0,01 inHg | |
| Measurement interval: 48 seconds | ||
| Duration of the alarm: 120 seconds | ||
| External | ||
| Measurement function | ||
| Air temperature | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| -40 ... 60 °C | 0,1 | The following conditions shall apply: |
| -40 ... 140 °F | ||
| Measurement function | ||
| Relative humidity | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 1 ... 99 percent | 1 % | ± 4% within 20 ... 80 percent |
| ±6 % outside 20 ... 80 percent |
||
| Measurement function | ||
| Pluviometry | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 0 ... 9999 mm | 0,3 mm to < 1000 mm | ± 6% |
| 1 mm to > 1000 mm | ||
| Measurement function | ||
| Wind speed | ||
| Measurement range | Resolution adopted by the Council | Accuracy |
| 0 ... 50 m/s | 0,1 | ± 1 m/s to < 5 m/s |
| 0 ... 100 mph | ± 10% at > 5 m/s | |
| Radio transmission: up to a maximum of 100 m, 300 feet | ||
| Frequency: 868 MHz (Europe) | ||
| Measurement interval: 48 seconds | ||
| Type of protection: IP X3 | ||
| Other specifications | ||
| Screen | 7" backlit touch | |
| Set the time | Manual and automatic (DCF 77) | |
| Powering of the screen | 3 x 1,5 V AA | |
| Power supply of the external module | 2 x 1,5 V AA | |
| Screen dimensions | Other, of a thickness of not more than 150 mm | |
| Dimensions of the outer module | Other, of a thickness of not more than 600 mm | |
| Weight of the screen | Approximately 551 g | |
| Weight of the outer module | Approximately 545 g | |
| Screen functions | ||
| - Indoor temperature in degrees Celsius or Fahrenheit | ||
| - Outdoor temperature in degrees Celsius or Fahrenheit | ||
| - Relative humidity of the interior | ||
| - External relative humidity | ||
| - Indication of atmospheric pressure in inHg or hPa | ||
| - Selection of relative or absolute atmospheric pressure | ||
| - Indication of rainfall in mm or inches | ||
| - Indication of rainfall for 1 hour, 24 hours, 1 week, 1 month or since the last zeroing | ||
| - Indication of dew point | ||
| - Weather forecasting | ||
| - The trend in weather forecasting | ||
| - Storm warning | ||
| - Indication of the weather values | ||
| - Programmable alarm functions for different weather values | ||
| - Memorize the maximum and minimum values received | ||
| - Selection of wind speed in mph, km/h, m/s, knots or Beaufort | ||
| - Indication of wind direction | ||
| - Wind Chill (thermal sensation) | ||
| - LED screen with background lighting | ||
| - Weather station battery life approximately 1 to 2 years | ||
| - Radio clock | ||
| - Indication in 12 to 24 hours | ||
| - Calendar . | ||
| - Adjustment of the time band | ||
| - Energy saving function | ||
| - Possibility of mounting it on the wall or installing it standing | ||
| - Permanent adjustment of the weather values | ||
| - Cyclical memory for 4080 complete weather records | ||
| (adjustable recording interval 5 to 240 min.) | ||
| Adjustment of the alarm functions in the weather station | ||
| - Maximum humidity alarm of the indoor air | ||
| - Maximum indoor temperature alarm | ||
| - Maximum outside humidity alarm | ||
| - Maximum outside temperature alarm | ||
| - Wind chill alarm maximum | ||
| - Maximum dew point alarm | ||
| - Maximum air pressure alarm | ||
| - Maximum wind speed alarm | ||
| - Maximum windsweep alert | ||
| - Maximum rainfall alarm, 1 hour | ||
| - Maximum rainfall alert, 24 hours | ||
| - Minimum humidity alarm of the indoor air | ||
| - Minimum indoor temperature alarm | ||
| - Minimum humidity alarm of the outside air | ||
| - Minimum outside temperature alarm | ||
| - Wind chill alarm is minimal | ||
| - Minimum dew point alarm | ||
| - Minimum air pressure alarm | ||
| Memorized measurement values (with date and time) | ||
| - Maximum rainfall for 1 hour | ||
| - Maximum rainfall for 24 hours | ||
| - Maximum rainfall for 1 week | ||
| - Maximum rainfall for one month | ||
| - Minimum humidity of the indoor air | ||
| - Minimum indoor temperature | ||
| - Minimum humidity of the outdoor air | ||
| - Minimum outside temperature | ||
| - Wind Chill is minimal | ||
| - Minimum dew point | ||
| - Minimum atmospheric pressure | ||
| - Maximum humidity of the indoor air | ||
| - Maximum indoor temperature | ||
| - Maximum humidity of the air | ||
| - Maximum outside temperature | ||
| - Wind chill maximum | ||
| - Maximum dew point | ||
| - Maximum atmospheric pressure | ||
| - Maximum air speed | ||
| - Wind direction | ||
| - Maximum of air bursts | ||