General purpose cylinder air needle type sensor head

General purpose cylinder air needle type sensor head

GT2-PA12 Sensor Specifications

This document outlines the specifications for the GT2-PA12 sensor.

System

  • Detection System: Scale Shot System II, absolute type (no tracking errors)

Measurement Range

  • 12 mm / 0.47"

Resolution

  • 0.5 µm / 0.02 Mil

Indicated Accuracy

  • 2 µm / 0.08 Mil (p-p) *1

Measuring Force

  • Mounting Down: 1.2 N *2
  • Mounting Lateral: 1.15 N *2
  • Mounting Up: 1.1 N *2

Sampling Cycle

  • 4 ms

Fluid Used

  • Clean, dry air

Operation Indicator Light

  • 2-color LED (red, green)

Environmental Resistance

  • Protection Grade: IP67 (IEC)
  • Pressure Resistance: 0.5 MPa
  • Applied Pressure Range: 0.24 to 0.26 MPa
  • Ambient Temperature: 0 to +55 °C / 32 to 131 °F (No freezing)
  • Relative Humidity: 35 to 85 % HR (No condensation)
  • Vibration Resistance: 10 to 55 Hz, Double Amplitude 1.5 mm / 0.06", 2 hours in each of the X, Y and Z directions
  • Shock Resistance: 1,000 m/s *2 (IEC60068-2-27)

Materials

  • Main Housing: SUS 303, Status Indicator: PET, Head Relay Connector Cable: PUR, Relay Connector: PBT, Plunger: SUS430 (Fluorine Coated)
  • Contact: Stainless Steel Type 304, 440C *3

Cable for Head

  • Optional (connects to relay connector)

Weight

  • Approx. 35 g (excluding cable) *4

*1 Value when the ambient temperature is 20 °C / 68 °F.

*2 Value at the center of the measurement range. Please note that the measuring force changes depending on the installation state of the dust covers.

*3 The contact is included with the sensor.

*4 Including the relay connector.


Products Related