CO2 gas detector with large screen / Bar graphic / Maintenance free CO2 sensor / Additional temperature and humidity indication / Range up to 9999 ppm / For classrooms, public institutions, etc.
The CO2 gas detector with an innovative design is a large screen for controlling indoor air quality. These can be meeting rooms, living rooms, or also public places such as schools and kindergartens. Thanks to its dimensions of 388 x 288 x 43 mm it can read the values
The NDIR CO2 sensor integrated measures in a range up to 9999 ppm. The peculiarity of the NDIR CO2 sensor is that, in addition to having a high measurement range, it requires no maintenance.
The CO2 gas detector also has a bar chart that allows you to see the CO2 concentration graphically. In addition, the CO2 gas detector has a green, yellow and red color division. These symbols are illuminated according to the CO2 concentration in the environment. Thanks to this
The NDIR CO2 sensor integrated measures in a range up to 9999 ppm. The peculiarity of the NDIR CO2 sensor is that, in addition to having a high measurement range, it requires no maintenance.
The CO2 gas detector also has a bar chart that allows you to see the CO2 concentration graphically. In addition, the CO2 gas detector has a green, yellow and red color division. These symbols are illuminated according to the CO2 concentration in the environment. Thanks to this
- Wall mounting, for large rooms
- Adjustment of the alarm values
- NDIR CO2 sensor, free from maintenance
- With temperature and humidity sensor
- Large LED display with bar chart
- Powered by network cable
- Not suitable for high humidity environments, such as swimming pools
- Adjustment of the alarm values
- NDIR CO2 sensor, free from maintenance
- With temperature and humidity sensor
- Large LED display with bar chart
- Powered by network cable
- Not suitable for high humidity environments, such as swimming pools
| CO2 | |
| Rate | 0 ... 9999 ppm |
| Accuracy | ±70 ppm ±5 % of the value |
| Resolution adopted by the Council | 1 ppm |
| The temperature | |
| Rate | -10 ... +100 °C |
| Resolution adopted by the Council | The following conditions shall apply: |
| Accuracy | The following conditions shall apply: |
| Relative humidity | |
| Rate | 0,9%, 99,9% of H.r. |
| Resolution adopted by the Council | 0,1% H.r. |
| Accuracy | ± 3% |
| Generic specifications | |
| The following information shall be provided: | CO2 Good / Green: 0 to 500 ppm CO2 OK / Yellow: 600 to 1100 ppm Low CO2 / Red: 1200 to 9999 ppm |
| Repeatability | Other, of a kind used for the manufacture of goods |
| Response time | 10 seconds |
| Operating conditions | 0 ... +50 °C, 0 ... 90 % H.r., not condensed |
| Storage conditions | -30 ... +70 °C, 0 ... 90% H.r., not condensed |
| Food | The following conditions shall apply: |
| Dimension | Other, of a thickness of not more than 30 mm |
| Weight | Other, of a kind used for the manufacture of goods |