Fiber Amplifier, Cable Type, Daughter Unit, PNP
- Code / Model:
- Manufacturer: Keyence
- Department: Automation and control of processes
- Category of products: Manufacturing equipment
- Sub-category: Fixed network analyzers
- You've seen it before.: 6
FS-N14P Specifications
Model
FS-N14P
Type
High Functionality, 2 Outputs
Cable
Emission
Output Type
PNP
Main Unit/Expansion Unit
Expansion Unit
Control Output
2 PNP open-collector 24 V; max. 1 output: 100 mA or less; total 2 outputs: 100 mA or less (single use)/20 mA or less (multiple connections); residual voltage 1 V or less
External Input
1
Input Time
2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)
Response Time
- 50 µs (HIGH SPEED)
- 250 µs (FINE)
- 500 µs (TURBO)
- 1 ms (SUPER)
- 4 ms (ULTRA)
- 16 ms (MEGA)
Multiple Connections to Expansion Units
Up to a total of 16 units can be connected (the two-output unit counts as two units).
Light Source
Red, 4 LEDs
APC
Selectable ON/OFF (Factory setting: OFF)
Number of Units with Interference Prevention
- 0 for HIGH SPEED;
- 4 for FINE;
- 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)
Rated Value
Power Supply Voltage
12 - 24 VCD ±10 %, ripple (P-P) 10 % or less
Classification
Current Consumption
- Normal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)
- Eco Mode On: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)
- Eco Full Mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)
Ambient Resistance
- Ambient Light: 20,000 lux or less (incandescent lamp), 30,000 lux or less (sunlight)
- Ambient Temperature: -20 to +55 °C / -4 to 131 °F (No freezing)
- Relative Humidity: 35 to 85 % HR (No condensation)
Vibration Resistance
10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions
Shock Resistance
500 m/s2, 3 times in each of the X, Y, and Z directions
Housing Material
Main unit and expansion unit cover material: Polycarbonate
Weight
Approx. 70 g