Fiber Amplifier FS-V21R Keyence

Fiber Amplifier FS-V21R Keyence

Model

FS-V21R

Type

Main Unit:4-element LED

Light Source

Red LED, 4 elements

Response Time

250 μs (FINE)/500 μs (TURBO)/1 ms (SUPER TURBO)/4 ms (ULTRA TURBO)/500 μs (HIGH RESOLUTION)/50 μs (HIGH SPEED)

Output Selection

Light-ON/DARK-ON (selected by selector)

Detection Mode

  • Light Intensity
  • Rising Edge
  • Falling Edge

Change Function

±1.999 max. (variable)

Time Delay Function

Mode

  • Timer OFF
  • Delay OFF
  • Delay ON
  • Single Action, selectable

Precision

±10% of the Prefixed Value

Variable Range

1 to 30 ms (in increments of 1 ms), 30 to 50 ms (in increments of 2 ms), 50 to 200 ms (in increments of 10 ms), 200 to 500 ms (in increments of 50 ms)

Output Control

Open Collector NPN 100 mA max. (40 VCD max.) *1, Residual Voltage: 1 V max.

Monitor Output

– *2

Expansion Units

Up to 16 expansion units can be connected (for a total of 17 units). *3

Mutual Interference Suppression

HIGH SPEED/HIGH RESOLUTION: 0, FINE: 4, TURBO/SUPER/ULTRA: 8

Size

30 mm (high) x 9 mm (wide) x 70 mm (depth) 1.18" (high) x 0.35" (wide) x 2.76" (depth)

Classification

Power Supply Voltage

12 to 24 VCD ±10%, ripple: 10% max., Class 2

Power Consumption

Normal

S-APC OFF: 650 mW max. (27 mA max. with 24 VCD), S-APC ON: 720 mA max. (30 mA max. with 24 VCD)

Semi-Eco

S-APC OFF: 530 mW max. (22 mA max. with 24 VCD), S-APC ON: 660 mA max. (25 mA max. with 24 VCD)

Eco Total

S-APC OFF: 480 mW max. (20 mA max. with 24 VCD), S-APC ON: 550 mA max. (23 mA max. with 24 VCD)

Ambient Resistance

Ambient Illumination

Incandescent Light: 20,000 lux max., Sunlight: 30,000 lux max.

Operating Ambient Temperature

From -10 to +55°C 14 to 131°F, no freezing *5

Operating Ambient Humidity

35 to 85% HR (no condensation)

Vibration

10 to 55 Hz, Double Amplitude: 1.5 mm 0.06", 2 hours each on the X, Y and Z axes

Shock Resistance

500 m/s *2 in the X, Y and Z directions, 3 times respectively

Structure Material

Polycarbonate

Weight

Approx. 80 g

Notes

  • *1 20 mA maximum for the expansion unit.
  • *2 Use the FS-V21RM in FINE or TURBO mode when transmitting signals with a monitor.
  • *3 If more than one unit is used, the ambient temperature will vary. Mount the units on the DIN rail with mounting hardware and verify that the output current is less than 20mA. 1 or 2 units: -10 to +55°C 14 to 131°F, 3 to 10 units: -10 to +50°C 14 to 122°F, 11 to 16 units: -10 to +45°C 14 to 113°F
  • *4 When HIGH RESOLUTION is selected, S-APC is set to ON. When HIGH SPEED is selected, S-APC is set to ON for type R, and for any type other than R, S-APC is set to OFF. For others, the factory setting is S-APC OFF. The value in parentheses is the current consumption when using a 24 VCA supply voltage.
  • *5 If two or more units are used, the ambient temperature will vary according to the following conditions. Mount the units on the DIN profile with mounting hardware and verify that the output current is 20 mA or less. 1 to 2 units: -10 to +55°C 14 to 131°F, 3 to 10 units: -10 to +50°C 14 to 122°F, 11 to 16 units: -10 to +45°C 14 to 113°F

Products Related