Higrómetro PCE-780-ICA incl. certificado de calibración ISO

Higrómetro PCE-780-ICA incl. certificado de calibración ISO

  • Code / Model:
  • Manufacturer: PCE Instruments
  • Department:
  • Category of products:
  • Sub-category: Instruments and equipment
  • You've seen it before.: 1
Higrometer with temperature, humidity and dew point temperature indication / Visual alarm / Backlighting / Automatic disconnection / Incl. ISO calibration certificate
The PCE-780 hygrometer has an infrared temperature sensor and a humidity sensor built in. With these two sensors, the hygrometer determines the dew point. If the dew point is reached or exceeded, there is a risk that moisture will occur and as a result,

The PCE-780 hygrometer also integrates a relative measurement function. For example, for the analysis of a building it can memorize a temperature of a certain point as a reference. Then, while performing several measurements, a color bar chart will give you a good or bad rating

- Infrared temperature measurement
- Measurement of air temperature and humidity
- Calculation of dew point
- High contrast LCD screen
- Adjustment of high and low limit values
- Minimum, maximum and average values
- Connector for external temperature sensor
- Adjustment of the emission levels
- Including ISO calibration certificate

Infrared

Measurement range

-60 ... +500 °C

Precision (ambient temperature between 20 and 26 °C)

15 ... 35 °C
-33 ... +500 °C

The following conditions shall apply:
± 2% of the value or ±2 °C

Resolution adopted by the Council

The following conditions shall apply:

 

Other, of a kind used for the manufacture of goods

Measurement range

-64 ... +1400 °C

Precision (ambient temperature between 20 and 26 °C)

± 1% of the value or ±1 °C

Resolution adopted by the Council

1 °C

 

Air temperature

Measurement range

-20 ... +65 °C

Precision (ambient temperature between 20 and 26 °C)

The following conditions shall apply:

Resolution adopted by the Council

The following conditions shall apply:

 

Temperature of the wet bulb

Measurement range

-20 ... +65 °C

Precision (ambient temperature between 20 and 26 °C)

The following conditions shall apply:

Resolution adopted by the Council

The following conditions shall apply:

 

Roost point

Measurement range

-50 ... +50 °C

Precision (ambient temperature between 20 and 26 °C)

20 ... 30 percent H.R.
31 ... 40 percent H.R.
41 ... 95 percent H.R.

The following conditions shall apply:
±2 °C
Other, not further worked than hot-rolled

Resolution adopted by the Council

The following conditions shall apply:

 

Humidity of the air

Measurement range

1 ... 99% H.R.

Precision (ambient temperature between 20 and 26 °C)

20 ... 80 percent:
Outside that range

± 3%
± 5%

Resolution adopted by the Council

The following conditions shall apply:

 

Other specifications

Degrees of emissivity

0,1 ... 1

Response time

1 second

Distance to measuring point ratio

12 : 1

Food

2 x 1.5 V batteries, type AA

Operating time
(without laser or background lighting)

About 180 minutes.
The test is performed in a test tube.

Weight

Approximately 240 g

Dimension

Other, of a width of not more than 30 mm



Products Related