Fiber Amplifier, Zero Line Child Unit
- Code / Model:
- Manufacturer: Keyence
- Department: Automation and control of processes
- Category of products: Controllers, HMI Displays and IoT Gateways
- Sub-category: Controllers, PLCs and Automates
- You've seen it before.: 1
FS-N10 Model Specifications
General
Type: 0 line
Main Unit/Expansion Unit: Expansion Unit (Without Output Line)
Control Output: None
Response Time
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
Expansion Units
- Up to a total of 16 units can be connected (the two-output unit counts as two units).
Indicators
Red, 4 LED elements
APC
Selectable ON/OFF (Factory default: OFF)
Interference Prevention Units
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)
Power Supply
Nominal Voltage: 12 - 24 VCD ±10 %, ripple (P-P) 10 % or less
Classification
Consumption Current
- Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)
- Eco Mode On: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)
- Eco Full Mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)
Environmental Resistance
Ambient Light
Incandescent Lamp: 20,000 lux or less, Sunlight: 30,000 lux or less
Ambient Temperature
-20 to +55 °C (-4 to 131 °F) (No freezing)
*Note:*- One or more connected units: -20 to +55 °C (-4 to 131 °F)
- 3 to more than 10 connected units: -20 to +50 °C (-4 to 122 °F)
- 11 to more than 16 connected units: -20 to +45 °C (-4 to 113 °F).
Relative Humidity
35 to 85 % HR (No condensation)
Vibration Resistance
10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y and Z directions
Shock Resistance
500 m/s2, 3 times in each of the X, Y and Z directions
Enclosure Material
Polycarbonate (Main Unit and Expansion Unit cover)
Weight
Approx. 20 g
*Notes:*- *1 One output is counted when added to a NU series communication unit.
- *2 Increases 100 mW (4.0 mA) for High Speed mode.
- *3 All temperature standards apply when the unit is mounted on a DIN rail and installed in metal sheets.