Reflective square cable, 100mm

Reflective square cable, 100mm

Model

LR-ZB100P

Type

Distance Adjustment

Shape

Rectangular

Emission

PNP

Cable Connection

2 m Cable

Detectable Distance

35 to 100 mm (1.38" to 3.94") (650 to 0)

Detection Deviation

  • Standard: 35 to 50 mm (1.38" to 1.97") : ± 1.5 mm (0.06")
  • 50 to 100 mm (1.97" to 3.94"): ± 3 mm (0.12")

Display Resolution

2 (0.2 mm / 0.008")

Dot Diameter

2 × 1 mm (0.08" x 0.04") to 100 mm (3.94")

Response Time

1.5 ms / 10 ms / 50 ms selectable

Light Source

Type

Red Laser (660 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part 1040.10 *2)

Function

  • Indicator: 3-digit and 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1-point indicator (green)
  • Timer: OFF / Delay ON / Delay OFF / Once

Classification

Power Supply Voltage

10 to 30 VDC, including 10% harmonic superior (P-P), Class 2 or LPS

Power Consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Specifications

Control Output

  • Open-Collector PNP
  • Applied Voltage: 30 VDC or less
  • Control Current: 100 mA or less
  • Residual Voltage: 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection Circuit

  • Reverse Polarity Protection
  • Output Overcurrent Protection
  • Output Overvoltage Protection
  • Output Inversion Protection

Output Operation

Selectable between Light-ON or Dark-ON

External Input

  • Calibration Time Input: 35 ms or more ON, 35 ms or more OFF
  • Laser Emission Stop: 2 ms or more ON, 20 ms or more OFF
  • Short-Circuit Current: 2 mA or less *3

Environmental Resistance

Degree of Protection

IP68 (IEC60529)/IP69K (DIN40050-9)/4X, 6P, 13 (NEMA250)

Insulation Photosensitive Resin

20 MΩ or more (500 V DC)

Ambient Light

  • Incandescent Lamp: 4,000 lux or less
  • Sunlight: 8,000 lux or less *4

Ambient Temperature

-10 to +50 °C (14 to 122 °F) (No Freezing)

Storage Temperature

-25 to +75 °C (-13 to 167 °F) (No Freezing)

Relative Humidity

35 to 85% HR (No Condensation)

Non-Disruptive Voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration Resistance

10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y, and Z directions

Shock Resistance

1,000 m/s² , 6 times in each of the X, Y, and Z directions

Material

  • Housing: SUS316L
  • Display: PES
  • Lens Cover: PMMA with Anti-Scratch Coating
  • Connector/Sealing Ring: FKM

Accessories

Instruction Manual, Certification/Identification Label (FDA)

Weight

Approx. 110 g (cable included)

*1 Reading of the display used as a guide for the detection distance. When determining the adjustment value, the reading is shifted. When the value exceeds “-99", it displays “-FF". *2 The US FDA (CDRH) laser identification is implemented according to IEC60825-1 in compliance with the requirements of Laser Notice No.50. *3 The M8 (3-pin) connector type does not include the external input function. *4 When the response time is 10 ms