Outback FM80
- Code / Model: Outback FM80 Regulador de Carga Maximizador Flexmax
- Manufacturer: Outback
- Department: Batteries, batteries and chargers
- Category of products: Chargers and Power Banks
- Sub-category: Solar chargers
- You've seen it before.: 9
Maximizer Flexmax Outback FM 80A MPPT
The Outback FM80 is an MPPT (Maximum Power Point Tracking) charge controller designed for photovoltaic systems up to 7500W. It offers high conversion efficiency and precise load regulation, ensuring maximum performance and battery protection.
Technical Features
Voltage
- Nominal battery voltages: 12, 24, 36, 48 or 60 VDC (selectable when powering on the unit)
- Open circuit voltage PV array: 150VDC (maximum value under low temperature conditions) / 145VDC for startup and maximum operating conditions
- Voltage regulation adjustment points: From 10 to 60 VDC, user-adjustable with password protection
Current
- Maximum output current: 80 amps @ 40ºC/104ºF with adjustable current limit
Power
- Maximum PV array power:
- 12VDC systems: 1250W
- 24VDC systems: 2500W
- 48VDC systems: 5000W
- 60VDC systems: 7500W
Other Features
- Charge regulation: Five states: bulk charge, absorption, float, standby and equalization
- Equalization voltage: Programmable voltage and timing - Automatic completion
- Battery temperature compensation: Automatic with optional RTS (remote temperature sensor) / 5.0 mV per ºC per 2VDC battery cell
- Reduced voltage capacity: Allows charging a lower voltage battery with a higher voltage PV array - Max 150 VDC
- Auxiliary control output: Programmable 12VDC output available for different applications (max. 0.2A DC)
- Information display: 8cm (3.1”) backlit LCD screen with 4 lines and 80 characters
- Display and remote controller: Optional - MATE or MATE2 with RS232 serial port for communications
- Data network connection: OutBack Red OutBack data network via RJ45 connector with CAT 5e (8-wire) cable
- Data logging: Last 128 days - Ah, Wh, peak W, Amps, PV voltage, time in float, battery max and min voltage, absorption for each day plus accumulated values of Ah and kWh
- Wind/hydraulic energy: Consult manufacturer for compatible systems
- Positive to ground systems: Bipolar switch required to disconnect positive and negative conductors in PV array and battery. (HUB4 or HUB10 use is not recommended in positive to ground systems)
- Operating temperature range: -40ºC to +60ºC (Output power derates from 40ºC)
- Environmental category: For indoor installation
- Connection holes: One 35mm (1”) rear; One 35mm (1”) left; Two 35mm (1”) bottom
- Warranty: 5 years
- Equipment weight: 5.56 Kg. - 12.20 lbs
- Shipping weight: 7.10 Kg. - 15.75 lbs
- Dimensions (height x width x depth): Equipment 41.3x14x10 cm. - 16.25 x 5.75 x 4”
- Shipping: 53 x 27 x 25 cm - 21 x10.5 x 9.75”
- Options: Remote temperature sensor (RTS), HUB4, HUB10, MATE and MATE2
- Menu languages: Spanish and English on the same unit