Sensor de CO2 PCE-WMM 5
- Code / Model:
- Manufacturer: PCE Instruments
- Department:
- Category of products:
- Sub-category: Instruments and equipment
- You've seen it before.: 1
Interior CO2 sensor and measuring converter, self-calibration, with multi-range switching and active output/manoeuvrability
Active output/manoeuvre-capable, automatic calibration (disconnectable), in a beautifully shaped plastic case with an elastic-pressure fitting cap, optionally with a traffic light indicator (five coloured LEDs), to determine the CO2 content of air (0
The sensor is used in offices, hotels, conference rooms, housing, commercial premises, etc. and serves to assess the ambient climate. This makes it possible to ventilate the space energy-saving and adapted to the needs and, with it, reduce service costs and increase well-be
CO2 measurement is carried out by NDIR (non-dispersive infrared technology) optical sensor. The detection range is adjusted from standard applications, such as monitoring of housing and conference rooms.
The sensor is used in offices, hotels, conference rooms, housing, commercial premises, etc. and serves to assess the ambient climate. This makes it possible to ventilate the space energy-saving and adapted to the needs and, with it, reduce service costs and increase well-be
CO2 measurement is carried out by NDIR (non-dispersive infrared technology) optical sensor. The detection range is adjusted from standard applications, such as monitoring of housing and conference rooms.
- For interiors
- CO2 range: 0 .... 2000 ppm / 0 ... 5000 ppm (switched)
- Output: 0-10 V / 4 ... 20 mA (switched)
- What ?Includes relay
- CO2 range: 0 .... 2000 ppm / 0 ... 5000 ppm (switched)
- Output: 0-10 V / 4 ... 20 mA (switched)
- What ?Includes relay
| The following information shall be provided: | |
| Rate | 0 .... 2000 ppm / 0 ... 5000 ppm (switched) |
| Out of the way | 0-10 V / 4 ... 20 mA (switched) |
| Equipment | Relay |
| Food | 24 V AC/DC (± 10%) |
| Energy consumption | The following conditions shall apply: < 2,9 VA / 24 V AC typical; Peak current 200 mA |
| Sensor | The following information shall be provided: with manual calibration (by the Zero button), with automatic calibration (disconnectable via DIP switch) |
| Accuracy | Typical ±30 ppm ±3 % of the value |
| Based on temperature | ±5 ppm / °C or ±0,5% of the measurement value / °C (the highest value) |
| Sensitivity to pressure | The following is the list of the products used: |
| Long-term stability | < 2% in 15 years |
| Gas exchange | Diffusion |
| The temperature of the room | 0 ... 50 °C |
| Starting time | About an hour. |
| Response time | < 2 minutes |
| Electrical connection | 0,14 - 1,5 mm2, screw piers |
| Carcass | ABS plastic, pure white (equivalent to RAL9010) |
| Dimension | 85 x 85 x 27 mm |
| Assembly | Wall or casing mountings |
| Protection class | The following conditions shall apply: |
| Type of protection | The following information is provided by the manufacturer: |
| The Commission shall adopt a decision on the | The Commission shall adopt implementing acts in accordance with Article 21 of Regulation (EC) No 1069/2009 and with the opinion of the European Parliament and of the Council. |