Pito tube pressure gauge / LCD backlit screen / Measurement of air speed, pressure, flow rate and ambient temperature / Memory for 99 values per parameter / Data analysis software
The pitot tube manometer is a device used in different sectors. This is because the pitot tube manometer allows you to measure several parameters, such as air speed, atmospheric pressure, flow rate and ambient temperature. The pressure manometer follows the principle of the pitot tube.
The manometer uses a pitot tube, which allows measuring air speeds up to 80 m/s. The construction of the pitot tube makes measuring in narrow places, small holes or small-sized pipes easy. The internal memory of the pitot tube manometer allows recording
This interface also allows real-time reading. Once the connection has been established you can see all the values in the software. As the pitot tube manometer is a tool for use in different fields of application, special interest has been placed in having a robust measuring instrument, which can be used in different
The manometer uses a pitot tube, which allows measuring air speeds up to 80 m/s. The construction of the pitot tube makes measuring in narrow places, small holes or small-sized pipes easy. The internal memory of the pitot tube manometer allows recording
This interface also allows real-time reading. Once the connection has been established you can see all the values in the software. As the pitot tube manometer is a tool for use in different fields of application, special interest has been placed in having a robust measuring instrument, which can be used in different
- Measures speed, pressure and air flow
- It also measures ambient temperature
- Zero adjustment function
- Functions: MIN, MAX, AVR, REC and HOLD
- LCD screen backlit
- Indication of two values on the screen
- Ideal for measuring high air speeds
- Internal memory for 99 values
- USB interface and software
- Measurement in real time
- Measurement with pitot tube
- Standard and differential pressure measurement
- Optional: ISO calibration
- 2 connecting tubes (approximately 85 cm)
- Different units (adjustable)
- Automatic disconnection (can be deactivated)
- It also measures ambient temperature
- Zero adjustment function
- Functions: MIN, MAX, AVR, REC and HOLD
- LCD screen backlit
- Indication of two values on the screen
- Ideal for measuring high air speeds
- Internal memory for 99 values
- USB interface and software
- Measurement in real time
- Measurement with pitot tube
- Standard and differential pressure measurement
- Optional: ISO calibration
- 2 connecting tubes (approximately 85 cm)
- Different units (adjustable)
- Automatic disconnection (can be deactivated)
| Air pressure | |
| Measurement range | Other, not further worked than hot-rolled Other, not further worked than hot-rolled Other, not further worked than hot-rolled 509,8 mmH2O Other |
| Resolution adopted by the Council | 0,0001 psi 0,01 mbar 0,01 inH2O 0,1 mmH2O 1 Pa |
| Accuracy | ±0,3% of the bottom of the scale at 25 °C |
| Reproductivity | ±0,2% (maximum ±0,5% of the bottom of the scale) |
| Linearity / Hysteresis | ±0,29% of the scale bottom |
| Pressure range | Other |
| Maximum pressure | 10 psi |
| Response time | Typical 0.5 seconds |
| Units (selectable) | Other, of a kind used for the manufacture of goods |
| Air speed | |
| Measurement range | 1 ... 80 m/s The following conditions shall apply: The maximum speed of the vehicle shall be: The power of the engine shall be measured at the speed of the engine. 2 ... 154,6 knots |
| Resolution adopted by the Council | The following conditions shall apply: 1 ft/min The following conditions shall apply: 0,01 MPH 0,1 knots |
| Accuracy | Unit m/s: ±2,5% of the measurement value Unit ft/min, Km/h, MPH or knots: depending on air speed and pipe size |
| Flow | |
| Measurement range | 0 ... 99999 m3/min / 0 ... 99999 ft3/min |
| Resolution adopted by the Council | The following is the list of the following: |
| The temperature | |
| Measurement range | The following conditions shall apply: |
| Resolution adopted by the Council | The following conditions shall apply: |
| Accuracy | The following conditions shall apply: |
| Generic specifications | |
| diameter of the pitot tube | 8 mm |
| Length of connection tubes | 850 mm each |
| Length of pitot tube | Other, of a width of not more than 30 mm |
| Low battery status indication | Yes, I did. |
| Food | 1 x 9 V battery |
| Operating conditions | 0 ... +50 °C / < 90 % H.r. without condensation |
| Storage conditions | -10 ... +60 °C / < 90 % H.r. without condensation |
| Internal memory | 99 values per parameter |
| Interface | USB or other |
| Screen | LCD |
| Carcass | Other, of a thickness of not more than 0,01 mm |
| Dimension | Apparatus: 280 x 95 x 45 mm Other, of a thickness of not more than 0,15 mm |
| Weight (including pitot tube, pile and tubes) | Other, of a thickness of not more than 600 g |
| The pitot tube flowmeter integrates a thread at the back, allowing it to be mounted on a tripod. | |