Independent type controller, PNP type

Independent type controller, PNP type

Model

LK-G3001P

Type

Separate Model

Head Compatibility

Compatible

Number of Connectable Sensors

Maximum of two heads

Display

  • Minimum Display Unit: 0.01 µm
  • Display Range: ±9999.99 mm to ±9999.99 µm (Selectable among six steps)
  • Presentation Cycle: 10 times/sec.

Terminal Block

Analog Output Voltage

±10 V x 2 outputs, output impedance 100 Ω

Analog Current Output

4 to 20 mA x 2 outputs, maximum load resistance 350 Ω

Timer Input

Input with voltage OUT1

Adjustment Input

Auto-zero input

Remote Laser Interlock Input

Voltage-free input

Evaluation Output

PNP open-collector output for OUT1

Alarm Output

PNP open-collector output for OUT1 (N.C.)

Expansion Connector

Timer Input

Voltage input for OUT2

Adjustment Input

Auto-zero input

Program Change Input

Voltage input x 3 inputs

Laser-Off Input

Voltage input for head A/head B

Evaluation Output

PNP open-collector output for OUT2

Alarm Output

PNP open-collector output for OUT2 (N.C.)

Binary

Binary Output

Measurement data output (21 bits)

OUT1/OUT2 selectable

Open-Collector PNP Output

Synchronization Output

Open-collector PNP output

Binary Selector Output

Binary Selector Input

Voltage input

RS-232C Interface

Output of measurement data and control I/O (selectable up to a baud rate of 115200 bit/s)

USB Interface

USB Revision 2.0, High Speed (USB1.1 compatible) compliant

Main Functions

  • 2-OUT simultaneous measurement function
  • Calculation function
  • Average calculation function
  • Filter function
  • Calibration function
  • Measurement function
  • Auto-zero function
  • Sampling cycle adjustment function
  • Mutual interference prevention function
  • Data storage function
  • 8 program memory function
  • Eco mode
  • ABLE adjustment function
  • Target measurement adjustment function
  • ABLE calibration function
  • Transparent object measurement surface selection function
  • Statistical calculation function
  • Software connection function
  • Configuration support function
  • Head installation selection function
  • And others.

Rated Value

Power Supply Voltage

24 VCD ±10%, ripple (P-P) 10% or less

Classification

Maximum Current Consumption

When connecting one measuring head: 500 mA or less/

When connecting two measuring heads: 600 mA or less

Ambient Resistance

Temperature

0 to +50 °C (32 to 122 °F)

Relative Humidity

35 to 85% HR (No condensation)

Weight

Approx. 370 g

Notes

  • *1 Characteristics of open-collector PNP output: 50 mA Max. (30 V or less), residual voltage: 1.0 V or less.
  • *2 Characteristics of voltage input; Accumulation rate: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA.
  • Part of each input/output circuit of the LK-G shares a common internal ground. Make sure that no potential difference is generated between the common terminals due to potential differences between the cables or external devices. Refer to "Wiring Precautions" (page 2-4) for more information.
  • *2 The LK-G3001 model can be used independently. Display of the measurement value and parameter change can be performed from the display panel (LK-GD500) or the configuration support software (LK-H1W).